HMP−...−B−...−Z..−...
Festo HMP−...−B−...−Z..−... 0412NH English
27
5. Accelerate the work load in steps until the operating speed is reached.
Pease refer to the calculations for your application for the speed required.
Linear module type HMP−...−B−... must not strike hard against the intermediate
position.
Concluding the test run:
6. Make sure that the guide tube of the linear module is in the park position.
7. Exhaust linear module type HMP−...−B−... and the intermediate position module
HMP−...−B−...−Z..−....
6
Care and maintenance
S
If the intermediate position module is dirty, clean it with a soft cloth.
Permitted cleaning agents are:
soap suds (max. 60 °C)
all non−abrasive media.
S
Replace the buffer elements on the
housing (D) or on the stop lever (E) in
order to minimize noise:
if the stop lever can be heard to strike
hard
at the latest every 3 million switching
cycles.
Otherwise the intermediate position module
does not require any maintenance.