Fitting electric components
For position scanning:
S
Push the required number of proximity switches into the appropriate grooves
in acccordance with the table below.
With the intermediate position module there may, under certain circum
stances, be multiple switching cycles as a result of unfavourable tolerance
conditions. The setting direction of the proximity switches must therefore be
observed as shown in the following diagrams.
Scanning
Position of the
retracted stop
lever
Position of the
extended stop
lever
Position of the guide
tube (end position and
intermediate position)
HMP−...−B−...−
Z1A
−...
HMP−...−B−...−
Z1E
−...
Position
On the intermediate position module
2
(note plug−in direction)
On the sensor strip
9
Type (proximity
switches)
SME−10..−.../
SMT−10..−...
SME−8..−.../
SMT−8..−...
Fig.12
The recesses (B) and (C) in the end cover of
the linear module enable proximity switch
cables to be passed outside where they can
then be connected to the terminal strip of the
electric interface, module HMP−...−EL.
Fig.13
(B)
(C)