8
Care and maintenance
Warning
Uncontrolled moving masses can cause injury to people or damage to property
(danger of fingers being squashed). Controller signals can cause unintentional
movements of the ERMB.
S
Switch off the controller for all maintenance work on the ERMB and protect it
from being switched on again unintentionally.
S
If necessary, clean the ERMB with a soft cloth.
Cleaning agents: all non-abrasive media.
Optimizing the service life of the toothed belt with swivel angles less than 360°:
1. Carry out the following steps after every 2 million load changes:
– Turn the switching ring (E) 90° (
è
chapter 5 “Fitting electric components”)
– Dismantling the work load.
– Also turn the work load 90° in the same direction.
– Mount the work load again.
A different part of the toothed belt then comes into the loading zone of the
toothed gear.
2. Repeat the commissioning.
9
Repairs
Recommendation:
S
Return the product to our repair service for overhaul.
The necessary accurate adjustments and tests will then be taken into account.