DSMI-...
Festo DSMI-... 0102NH English
29
3. Loosen the locking screws for the stops.
The stops can then be shifted easily.
4. Shift the nearest stop up to the stop lever.
5. Tighten the locking screws of the stops
again with the specified torque.
Nominal size
DSMI-25
DSMI-40
Tightening torque
5.9 Nm
25 Nm
After completion of static pre-adjustment of
all the stops
without
a shock absorber:
6. press the protective cap of the DSMI-...
back onto the snap ring of the housing.
Fig. 16
Fig. 17