2. Commissioning
2−24
Festo P.BE−CPX−FB32−EN en 0605NH
2. Select the ETHERNET MODULE Generic Ethernet
Module" in the window Select Module Type" and confirm
with OK.
Fig.2/6:
Insert CPX−FB32 as Generic Module
3. Enter the following in the window Module Properties"
the name for the field bus node (as desired)
the Instances for inputs: 101
outputs: 100
the Instance for Configuration Assembly: 102
The standard setting is 0" (Configuration Assembly
not used).
Operating mode Remote I/O: If you undertake
parametrizing via the Configuration Assembly: Enter
the sum of the assigned bytes (see section 2.3.1).
Operating mode Remote Controller: Leave the stan
dard setting 0".