5
Diagnostics and error handling
Festo – P.BE-CPX-CTEL-EN – 1411a – English
47
CPX error
number
Error handling
Description of possible causes
17
Incorrect I/O length
CPX system start with setting “Stored
parameters” and CTEL master module in
operating mode “Automatic configura
tion”
Use system setting “Standard
parameter” at the start of the CPX
terminal
24
Process variable range underflow
Process data inconsistent, check
25
Process variable range overflow
Process data inconsistent, check
29
Parameter error
Invalid parameters received from the
host
Check parameterisation
Parameter error
Check data sheet and values
Missing parameters
Check data sheet
Changed parameter
Check configuration
39
Maintenance required
Process data inconsistent, check
56
Short circuit at I-port (PS/PL supply or
communication signal)
Check the installation
57
I-port device missing/failed
Check configuration
58
I-port configuration error
Check configuration
Tab. 5.3
Diagnostics/error messages by CPX error numbers
When the CTEL master module is accessed via FMT/MMI, the most current error for each
I-port can be determined more precisely by means of an event code if the error is due to
the connected device.
A list with the relevant event codes can be found in appendix A.2.
5.3
Diagnostics via LEDs
LED indicators for diagnostics of the CPX terminal are available on the CTEL master module and the
I-port devices.
Description of the LED indicators on the CTEL master module:
è
The significance of the LEDs on the I-port devices can be found in the description of the
respective module.
Содержание CPX-FB13