4. Diagnosis
4−6
Festo P.BE−CPX−CEC−EN en 1004a
ERROR PLC run−time error
LED (red)
Sequence
Status
Error number
Error handling
LED lights up
ON
OFF
PLC program error
CPX error
·
Read out error
code over
handheld or
CoDeSys pbF
LED is off
ON
OFF
No error
Tab.4/4:
Displays of ERROR LED
TP Ethernet connection: link/traffic
LED (green)
Sequence
Status
Error number
Error handling
LED lights up
ON
OFF
Ethernet connection OK
LED flashes
ON
OFF
Data transfer active
(LED flashes irregularly)
LED is off
ON
OFF
Ethernet connection to the
parameterisation PC not OK
·
Check
the connection
the IP address
Tab.4/5:
Displays of TP LED
Содержание CPX-CEC
Страница 2: ......
Страница 17: ...System summary 1 1 Festo P BE CPX CEC EN en 1004a Chapter 1 ...
Страница 33: ...Installation 2 1 Festo P BE CPX CEC EN en 1004a Chapter 2 ...
Страница 53: ...Commissioning 3 1 Festo P BE CPX CEC EN en 1004a Chapter 3 ...
Страница 68: ...3 Commissioning 3 16 Festo P BE CPX CEC EN en 1004a ...
Страница 69: ...Diagnosis 4 1 Festo P BE CPX CEC EN en 1004a Chapter 4 ...
Страница 76: ...4 Diagnosis 4 8 Festo P BE CPX CEC EN en 1004a ...
Страница 77: ...Technical appendix A 1 Festo P BE CPX CEC EN en 1004a Appendix A ...
Страница 82: ...A Technical appendix A 6 Festo P BE CPX CEC EN en 1004a ...
Страница 83: ...Index B 1 Festo P BE CPX CEC EN en 1004a Appendix B ...
Страница 84: ...B Index B 2 Festo P BE CPX CEC EN en 1004a ...