42
Festo — CMMT-AS-...-S1 — 2021-04d
Technical data
Diagnostic outputs STA and SBA at [X1A]
Voltage loss at high-
level
[V]
<
3
Permissible output cur-
rent at low-level
1)
[mA]
<
–400
Voltage loss at low-
level
[V]
<
1.5
Pull-down resistance
[kΩ]
<
50
Protective function
–
Short-circuit proof
–
Feedback-proof
–
Overvoltage-resistant up to 60 V
Loads
Ohmic load (min.)
[kΩ]
1.2
Inductive load
[μH]
<
10
Capacitive load
2)
[nF]
<
10
Test pulses
Test pulses at outputs
None (for time-offset test pulses on the associated A/B control
inputs)
1) Current flows from outside via the internal low-side switch to 0 V reference potential of 24 V supply
2) Requires connection of the output to a Type 3 input
Tab. 27: Diagnostic outputs STA and SBA at [X1A]
9.3.3
Inputs and outputs for the axis [X1C]
Output BR-EXT at [X1C]
Design
High-side switch
1)
Voltage range
[V DC]
18
…
30
Permissible output cur-
rent for high level
[mA]
100
Voltage loss at high
level
[V]
<
3
Pull-down resistance
[k
Ω
]
<
50
Protective function
–
Short-circuit proof
–
Feedback-proof
–
Overvoltage-resistant up to 60 V
–
Thermal overload protection