Signal name
Name
Function
Can be para-
meterised
X1A.3
Enable (CTRL-
EN)
Behaviour can be parameterised.
–
Behaviour 1: The closed-loop controller can
only be enabled over the drive profile when
high level is present.
–
Behaviour 2: With a rising edge, the control-
ler is enabled without taking into account the
drive profile. The drive is energised and is in
the operating mode requested in the signal
transfer.
–
Behaviour 3: Enabling of the controller can
only be controlled over the drive profile.
If the request is withdrawn, the drive is braked
with a behaviour of the stop category 1. After the
braking ramp ends, the brake is engaged and the
output stage is switched off functionally.
Yes
X1A.2
AIN0
X1A.1
#AIN0
Differential analogue input for typical input level
of ± 10 V
Through the analogue input, the following set-
point values and limits can be specified in the
form of analogue voltage:
–
Setpoint values for position, speed or
force/current
–
Limits for position or force/current
Yes
Tab. 23 Inputs and outputs at the connection [X1A]
Internal design of digital inputs (DIN) - does not apply for STO inputs
The following equivalent circuit shows an example of the internal design of a digital input (DIN).
The digital inputs are designed for +24 V level corresponding to type 3 in accordance with EN 61131-2.
The digital inputs are not galvanically separated and have integrated EMC protective functions.
Two-channel safe inputs correspond in their internal design to two 1-channel inputs. But the equival-
ent circuit is not valid for the STO inputs. Information on 2-channel safe inputs
è
textvar object does
not exist.