A
Technical appendix
Festo – GDCP-CMCA-B-INST-EN – 1405NH – English
39
Approval certificates
CMCA-...-B...-C-
CMCA-...-B...-CC-/-CS-
CE marking (see declaration of
conformity)
(
www.festo.com/sp)
–
–
EU EMC directive
1)
–
EU low voltage directive
1)
The device is intended for use in an industrial environment.
Measures for interference suppression may need to be implemented in residential areas.
Tab. A.4
A.1.3
Electrical data
Power supply
Mains voltage
[V AC]
230/400 / 3-phase
Mains frequency
[Hz]
50 … 60
Fuse protection on mains side
[A]
max. 20 (slow-blow)
Tab. A.5
A.1.4
Operating and environmental conditions
CMCA-...-B...-C-
CMCA-...-B...-CC-/-CS-
Ambient temperature
[°C]
+5 … +40 (outside the housing)
Storage temperature
[°C]
-20 … +60
Relative air humidity
[%]
10 … 95 (non-condensing)
Permissible setup altitude
above sea level
[m]
≤
1000
1000 … 2000 with output reduction of 10 %/1000 m
Cooling
About the ambient
atmosphere.
If installed in a control
cabinet, ventilation must be
planned.
About the ambient
atmosphere and control
cabinet fan.
Degree of protection
IP20
IP54
Relative air humidity
[%]
10 … 95 (non-condensing)
Degree of contamination in
accordance with
EN 61800-5-1
2
1)
2
1)
The integrated safety-engineering equipment requires compliance with degree of contamination 2 and thus a protected fitting
space. This must be ensured through corresponding measures, e.g. through installation in an appropriate control cabinet.
Tab. A.6