© Festo Didactic 8034153
41
6
Analog Output Connect
The port assignment of the Connect that
has been inserted into the base will be
displayed on the iPad after starting the
iEasyLab software.
6.1
Structure and function
The Analog Output Connect allows analogue voltages to be output via 2 output channels. A voltage range of
0 V...10 V or ±10 V can be set in iEasyLab under the “Settings” menu for the Connect. The electrical
connection is established via 4 mm safety sockets.
Assignment
Socket 0
Socket 1
Socket 2
Socket 3
Channel AOUT1: Signal
Channel AOUT1: GND
Channel AOUT2: Signal
Channel AOUT2: GND
6.2
Commissioning the Connect
Proceed as follows:
1.
Insert the Connect into the base.
2.
The Connect is detected automatically by the base.
3.
If the iEasyLab software has been started, the Connect will be detected and shown on the display.
6.3
Technical data
Electrical/mechanical specifications
Output voltage
±10 V
Output current
30 mA max.
Connection
4 mm safety sockets
Resolution
12 bit
Size
71 mm x 40 mm x 30 mm
Weight
42 g
Subject to change