Festo DADE-MVC 1503b English
26
Criteria
DADE-MVC
Inputs and outputs to the PLC:
– Polarity
– Characteristic
– Switch-on delay of the
inputs (debounce time)
PIN 3, 5, 6, 7 on the S1
PNP
EN 61131-2 (type 2)
Typical: 3 ms
Analogue output to PLC:
– Type DADE-MVC-010:
– Voltage range
– Load impedance
– Type DADE-MVC-420:
– Current range
– Load impedance (load)
PIN 2 and 4 on the S1
0.1 ... 9.9 V
R ≥ 1 kΩ
4.1 ... 19.9 mA
R ≤ 600 Ω
Protection against incorrect
polarity (PLC connection)
Yes
Electrical isolation:
Inputs/outputs/measured signal
No
Repetition accuracy depends on
the work stroke
≤ 400 mm: ±0.1 mm
≤ 500 mm: ±0.13 mm
≤ 750 mm: ±0.19 mm
≤ 1200 mm: ±0.3 mm
Linearity fault
±0.2 %, related to the calibrated
stroke
Signal run time
Max. 10 ms (from reaching the
position to outputting the
analogue value)