Festo DADE-MVC 1503b English
19
Caution
Measuring fault.
Non-permitted load impedances can falsify the
measurement results and indicate incorrect positions.
Observe at all costs the following load impedances
for faultless functioning:
– DADE-MVC-010: R ≥ 1 kΩ (0...10 V)
– DADE-MVC-420: R ≤ 600 Ω (4...20 mA)
Connect the cable of the PLC to connection S1 (
4
).
Fasten the plugs with the aid of the union nut.
Pin
Colour
Assignment
Connection S1
1
white
+24 V power supply
2
8
1
3
4
5
6
7
2
brown
Measured signal
(analogue)
3
green
Reference output
4
yellow
0 V measured signal
5
grey
Reference input
6
pink
Calibration input
7
blue
Ready output
8
red
0 V power supply and
inputs/outputs