DAPZ−...−AR
Festo DAPZ−...−AR 0512a English
25
7
Installation
Please note
These operating instructions assume that the rotary drive, on which the
DAPZ−...−AR is mounted, is fitted in a longitudinal direction to the tubing.
Mechanical installation
Before fitting:
1. Close the valves with the aid of the rotary drive.
2. Switch off all power supplies.
3. Make sure that the rotary drive, on which the DAPZ−...−AR is mounted, is not
pressurized.
Mounting the feet
Please note
The limit switch attachment DAPZ−...−AR is suitable for fitting two thread
spacings (80 mm and 130 mm).
S
Before fitting, note the two possible foot positions of the limit switch
attachment on the rotary drive.
1. Pull the feet out of both foot supports
of the limit switch attachment.
Fig.3
Содержание 534474