7. Fasten the coupling housing to the
DMES−... with the maximum number of
screws. (torque: see Fig.8).
8. Press the clamping element (see Fig.1)
into the hole on the side of the coupling
housing.
9. Press the motor with correctly placed
coupling hub into the coupling housing
(if necessary turn the motor).
10. Tighten the screw of the clamping
element (torque see Fig.8).
Fitting the product
Please note
S
Please note that in the case of heavy loadings the axis must not be
fastened only by the front cover.
Heavy tensile strain may cause the screws in the cover to be pulled out.
S
Note that the IP protection class will only be complied with if the product is
fitted correctly (protection against the penetration of dirt particles and drops).
Fitting position
IP protection class
Vertical, diagonal or horizontal with
cover band upwards
IP40
Diagonal or horizontal with cover
band downwards
IP42
Products with long stroke lengths:
S
Use the grooves as shown in Fig.9 for
fastening the DMES.
Fig.8
DME−KG−25:1.2Nm
DME−KG−40:9.9Nm
dia. 25: 2.9 Nm
dia. 40: 5.9 Nm
Fig.9
Ø25
Ø40