Festo CP-FB11-E 0112e English
21
Type
CP-FB11-E
Pin 1
Operating voltage connection for
electronics
– Rated value
– Tolerance
– Current consumption of the
CP-FB11-E
– Current consumption of the complete
CP system
24 V DC (protected against
incorrect polarity)
20.4...26.4 V
Max. 250 mA
See manual “CP system”,
current consumption table
Pin 2
Load voltage connection
– Rated value
– Tolerance
– Current consumption
24 V DC (protected against
incorrect polarity)
20.4...26.4 V
Sum of all switched-on CP
solenoid valves; see manual
“CP pneumatics”
Residual ripple
4 Vpp (within tolerance)
Detailed information on the CP FB11 can be found in the
manual P.BE-CP-FB11-E-.. .
Содержание 18227
Страница 12: ...Festo CP FB11 E 0112e Deutsch 12...
Страница 22: ...Festo CP FB11 E 0112e English 22...
Страница 52: ...Festo CP FB11 E 0112e Italiano 52...
Страница 62: ...Festo CP FB11 E 0112e Svenska 62...