1.3 Making Cable Connections
1.3.1 Cabling Overview
Genius II Quick Start Guide
0101-9031-0, Rev. B
2
1.3 Making Cable Connections
1.3.1 Cabling Overview
Section 1.3.2 describes how to connect the Genius II to the components it controls and to the required
interlock switches. For instructions on making connections between the Genius II and a PLC-based
system controller, see section 1.3.3.
WARNING
Connect the Genius II’s rear panel SWEEPER COILS connector only to e-beam
guns with beam-drive coils of ±3 A capacity in both the longitudinal and lateral
axes.
1.3.2 Basic Cabling Procedure
Figure 2 shows the connectors on the Genius II rear panel. The following procedure describes the basic
cabling connections to be made to via those connectors, and Figure 3 illustrates those cabling
connections. For additional details about connections to be made via rear panel connector X110, see
Figure 4 and Table 1. For details about connections to be made via rear panel connector X119, see
Figures 6 and 7.
Figure 2 Connectors on Genius II Rear Panel
Step
Action
1
Plug the male 9-pin connector on the Y-end of Cable 1-950040 into
Carrera rear-panel connector X302, as shown in Figure 3.
2
Plug the female 15-pin connector on the Y-end of Cable 1-950040 into
Carrera rear-panel connector X303.