Tempra 12 / 18
2. INSTALLATION
2.1 General instructions
This appliance must only be used for the purposes it has been specifically designed for. This appliance is
used to heat water to below boiling temperature at atmospheric pressure and must be connected to
a central heating and/or hot warm distribution system, according to its characteristics, performance
and heating capacity. All other uses are considered improper.
THE BOILER MUST ONLY BE INSTALLED BY SPECIALIST AND QUALIFIED PERSONNEL, IN
COMPLETE COMPLIANCE WITH ALL THE INSTRUCTIONS REPORTED IN THIS TECHNICAL MANUAL,
THE LEGAL STANDARDS IN FORCE, THE PRESCRIPTIONS OF STANDARDS AND ANY LOCAL
STANDARDS, AND ACCORDING TO THE RULES OF GOOD PRACTICE.
Incorrect installation may cause damager to persons and property. The manufacturer will not
be held liable in such events.
This appliance must be installed strictly in accordance with these instructions.
The Gas Safety Regulations (Installations & Use).
The Local Building Regulations.
The Building Regulations.
The Buildings Standards (Scotland - Consolidated) Regulations.
British gas publication DM2 - Guide for installation in timber framed housing.
British Standards Codes of Practice:
B.S. 7593
TREATMENT OF WATER IN DOMESTIC HOT WATER CENTRAL HEATING SYSTEMS
B.S. 5546
INSTALLATION OF HOT WATER SUPPLIES FOR DOMESTIC PURPOSES
B.S. 5440 Part
1
FLUES
B.S. 5440 Part 2
AIR SUPPLY
B.S. 5449
FORCED CIRCULATION HOT WATER SYSTEMS
B.S. 6798
INSTALLATION OF GAS FIRED HOT WATER BOILERS
B.S. 6891
GAS
INSTALLATIONS
B.S. 7671
IEE WIRING REGULATIONS
B.S. 4814
SPECIFICATION FOR EXPANSION VESSELS
B.S. 5482
INSTALLATION OF LPG
Model Water Bye Laws
For Northern Ireland the rules in force apply
2.2 Place of installation
The appliance’s combustion chamber is sealed from the surrounding environment and as a result the
appliance may be installed in any room without purpose built ventilation. The installation environment
must nonetheless feature sufficient ventilation, to avoid dangerous conditions arising in the event of
even minor gas leaks. These safety standards are imposed by EEC Directive no. 09/396 for all gas
appliances, including the so-called sealed appliances.
The place of installation must in any case be free of dust, inflammable objects or materials and corrosive
gases. The environment must be dry and not prone to freezing.
The boiler is supplied ready for wall-hung installation. The rear frame of the appliance has a series of
slots for fastening it to the wall, using screws with wall plugs. The fastening to the wall must provide
stable and effective support of the appliance.
The boiler must be fastened to a closed part of wall, which is free of apertures or holes behind the frame
of the boiler that may allow the internal components of the boiler to be reached.
If the appliance is enclosed in a cabinet or alongside another appliance, space must be allowed
for normal maintenance operations. Fig. 2 and Tab. 3 show the minimum and recommended space
to be left free around the appliance.