Table. 3- Accessories
2.7 Condensate drain connection
The boiler has a trap to drain condensate. Proceed as follows for assembly.
1. Secure the trap.
2. Before connecting the hose to the discharge system, fill the siphon with water.
3. Connect the hose from the trap to the condensate drain system.
B
ATTENTION: THE UNIT MUST NEVER BE OPERATED WITH THE TRAP
EMPTY!
OTHERWISE THERE IS A DANGER OF SUFFOCATION DUE TO THE EMIS-
SION OF COMBUSTION FUMES.
fig. 54- Condensate drain connection
Losses in m
eq
Air
intake
Fume exhaust
Vertical
Horizontal
Ø 100
PIPE
1 m M/F
041073X0
1.0
1.6
2.0
0.5 m M/F
041072X0
BEND
90° M/F
041077X0
1.5
2.0
TERMINAL
Antiwind discharge terminal
1KWMA29K
0,5lt