7.5 REPLACEMENT OF THE POWER CORD
ATTENTION
DO NOT TAMPER WITH THE
POWER CORD.
If the power supply cable is dam-
aged, it must be replaced by the
manufacturer or the technical as-
sistance service or in any case
by a person with similar qualifi-
cations, in order to prevent any
risk.
The cable must be replaced in compliance with the laws in
force in the country where the product is used.
Replace the damaged power cord with a new one with the
same or equivalent characteristics to the original cord.
8. REQUIREMENTS FOR THE
OPERATION, SERVICE AND
INSTALLATION OF APPLIANCES THAT
USE FLAMMABLE REFRIGERANT
GASES ACCORDING TO ANNEX DD OF
EN 60335-2-40
8.1 GENERAL WARNINGS
OBLIGATION
Any maintenance operation must
be performed by qualified per-
sonnel in accordance with the in-
structions in this manual.
OBLIGATION
Do not use any means to accel-
erate the defrosting or cleaning
process, other than those recom-
mended by the manufacturer.
OBLIGATION
The unit must be placed in a
room that does not have continu-
ous ignition sources (e.g. naked
flames, a gas appliance or elec-
tric heater in operation).
OBLIGATION
Do not pierce or burn.
OBLIGATION
Remember that refrigerant fluids
may be odorless.
OBLIGATION
R290
The appliance must be installed,
operated and placed in an instal-
lation space with an area greater
than 10 m
2
and a minimum height
of not less than 2 meters. The
overall volume of the installation
compartment must be greater
than 20 m
3
.
The air inlet and outlet of the ap-
pliance must be channelled to
the external environment as in-
dicated in paragraph 6.6 on page
136.
R290
The product is supplied with an
R290 refrigerant charge of 0.15
kg; any recharging operations
can only be performed at the
manufacturer's production site.
No repairs/replacements are al-
lowed on components that are
an integral part of the refrigerant
circuit.
8.2 FIRE RISK
The product must be installed in
a room equipped with adequate
air change to prevent the risk of
fire in case of a refrigerant gas
leak.
If the above is not possible, the
installer must carry out the nec-
essary work to ensure that no re-
frigerant gas stagnation occurs.
Содержание EGEA 120 LT
Страница 2: ...IT 3 ES 53 EN 105 PT 155 FR 205 ...
Страница 29: ...EGEA 90 LT 120 LT 29 cod 3541T580 Rev 06 04 2022 IT fig 21 fig 22 5 2 DATI DIMENSIONALI fig 23 fig 24 ...
Страница 79: ...EGEA 90 LT 120 LT 79 cód 3541T580 Rev 06 04 2022 ES fig 21 fig 22 5 2 DATOS DIMENSIONALES fig 23 fig 24 ...
Страница 131: ...EGEA 90 LT 120 LT 131 cod 3541T580 Rev 06 04 2022 EN fig 21 fig 22 5 2 DIMENSIONAL DATA fig 23 fig 24 ...
Страница 154: ...EGEA 90 LT 120 LT cod 3541T580 Rev 06 04 2022 154 EN PAGE INTENTIONALLY LEFT BLANK ...
Страница 181: ...EGEA 90 LT 120 LT 181 cód 3541T580 Rev 06 04 2022 PT fig 21 fig 22 5 2 DADOS DIMENSIONAIS fig 23 fig 24 ...
Страница 204: ...EGEA 90 LT 120 LT cód 3541T580 Rev 06 04 2022 204 PT PÁGINA INTENCIONALMENTE DEIXADA EM BRANCO ...
Страница 231: ...EGEA 90 L 120 L 231 code 3541T580 Rév 06 04 2022 FR fig 21 fig 22 5 2 DONNÉES DIMENSIONNELLES fig 23 fig 24 ...
Страница 254: ...NOTE ...
Страница 255: ...NOTE ...