Installation and maintenance manual
pag.
16
/
19
Parameter description
Code
u.m.
min
max
default Notes
Anti-Legionella function set
H1
°C/°F
10.0
199.0
65.0
Duration of Anti- Legionella function
H3
min
0
240
2
Digital 1 input enabling
i0
----
0
2
2
0 = Input disabled
1 = Input pressure
2 = GREEN input
Type of digital 1 input contact
i1
----
0
1
0
0 = Active if contact is
closed
1 = Active if contact is
open
High/low pressure end compressor
protection
i2 min
0 120
0
Photovoltaic input enabling i3
----
0
1
1
0 = Input disabled
1 = Input enabled
Type of photovoltaic input contact i4
----
0
1
0
0 = Active if contact
closed
1 = Active if contact
open
Number of digital input alarms per
equipment block
i8 ----
0 15 0
Time for digital input alarm counter reset
i9
min
1
999
240
Buzzer enabling u9
----
0
1
1
0 = Buzzer disabled
1 = Buzzer enabled
Switching on time for Monday Hd1
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Tuesday Hd2
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Wednesday Hd3
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Thursday Hd4
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Friday Hd5
----
1
2
1
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Saturday Hd6
----
1
2
2
1 = HOn1-HOF1
2 = HOn2-HOF2
Switching on time for Sunday Hd7
----
1
2
2
1 = HOn1-HOF1
2 = HOn2-HOF2
Time for first switch on timeslot
HOn1
----
00:00 23.59
--:--
--:-- = Function excluded
Time for first switch off timeslot
HOF1
----
00:00 23.59
--:--
--:-- = Function excluded
Time according to timeslot switch on
HOn2
----
00:00 23.59
--:--
--:-- = Function excluded
Time according to timeslot switch off
HOF2
----
00:00 23.59
--:--
--:-- = Function excluded
Equipment address
LA
----
1
247
247
Baud Rate Lb
----
0
3
2
0 = 2400
1 = 4800
2 = 9600