Installation and maintenance manual
pag. 5 / 19
3.2
Technical characteristics
Model
90
-
Heat pump
Supply
230-1-50
V-f-Hz
Heating capacity
(ISO)
1005
W
Total power input in heating
(ISO)
210
W
COP
(ISO)
4,79
W/W
Rated current input in heating
(ISO)
0,95
A
Max power input
270
W
Max current input
1,20
A
Warming up time
(EN) (1)
5:30
h:min
Warming energy
(EN) (1)
1,20
kWh
Stand-by input
(EN) (1)
14
W
Class of usage
(EN) (1)
M
Tipo
Power consumption during cycle of use WEL-TC
(EN) (1)
2,20
kWh
COPDHW
(EN) (1)
2,70
W/W
Reference temperature
(EN) (1)
50,8
°C
Max. quantity of water usable
(EN) (2)
0,094
m
3
Heating efficiency. Ref St.
(EU)
110
%
Energy efficiency. Ref St.
(EU)
A+
-
Annual power consumption
(EU)
465
kWh/anno
Electric heating
Capacity
1200
W
Input current
5,2
A
Heat pump + electric
heating
Total power input
1410
W
Total current
6,15
A
Max total power input
1470
W
Max current
6,40
A
Tank
Volume
87
l
Max. operating pressure
0,7
MPa
Material
enamelled steel
tipo
Protection
Anodo di Mg
tipo
Isolation type\thickness
polyurethane / 50
tipo/mm
Air circuit
Fan type
Centrifugal
tipo
Air flow
130
m3/h
Pipe outlet diameter
125
mm
Max available pressure
120
Pa
Refrigerant circuit
Compressor
Rotary
tipo
Refrigerant
R134a
tipo
Evaporator
finned copper-
aluminum battery
tipo
Condenser
aluminum tube
wrapped externally to
the tank
tipo
Indoor sound power level
60
dB(A)
Outdoor sound power level
64
dB(A)
Weight
Net
48,5
kg
Note
(ISO)
GDWDDFFRUGLQJWRWKHVWDQGDUG,62
(EN)
GDWDDFFRUGLQJWRWKHVWDQGDUG(1
(EU)
GDWDDFFRUGLQJWRWKHVWDQGDUG(8
(1)
KHDWLQJF\FOH$PELHQWWHPSHUDWXUH &%6&%8,QLWLDOZDWHUWHPSHUDWXUH &
(2)
XVHWHPSHUDWXUH&LQOHWZDWHUWHPSHUDWXUH&
Содержание AQUA PLUS 90 HT
Страница 79: ...NOTE...
Страница 80: ...HUUROL VSD 6DQ RQLIDFLR 9HURQD WDO 9LD 5LWRQGD WHO ID ZZZ IHUUROL FRP 2 4...