Installation and maintenance manual
pag. 10 / 23
4.2.1
Connection rotation
To use the suction and discharge side holes,
remove the covers A fig 3 originally positioned in
points (1a and 1b Figure 3) and move them in the
upper holes (2a and 2b Fig.3)
It is recommended to remove the two screws (B
particular Fig 3).
Fig. 3
4.2.2
Particular installation conditions
One of the peculiarities of the heat pump heating
system is represented by the fact that these units
cause a considerable reduction of the air
temperature that is generally ejected from inside
the home. Apart from being colder than the
ambient air, the exhaust air is also completely
dehumidified; for this reason, it is possible to allow
the air to flow back into the home in order to cool
specific environments or rooms during the summer.
Installation consists of the splitting of the discharge
pipe to which two shutters are applied (“A” and”)
with the aim of directing the air flow either towards
the outside or the inside of the home (Fig. 4b).
Fig. 4a – Example of installation in summer
Fig. 4b – Example of installation in winter
Outdo
or area
Inside
area
Outdoor
area
Inside
area
Shutter “A”
closed
Shutter “B”
open
Shutter “A”
open
Shutter “B”
closed