Installation
This is the standard configuration, where the gateway board (can be identified as Realtek Controller) is bridged
with the LAN port (Local Area Connection 2), which is used for connecting to a switch. The unused second LAN
port (Local Area Connection 3) is disabled. In some situations (e.g. due to different BIOS revisions), the physical
LAN adapters have different internal id’s, meaning that the restored configuration must be corrected manually.
Image 2.8: Example of a network configuration that needs to be corrected
End of Example
»
The necessary changes in this case are:
• Right click on Network Bridge – Properties
• Make Local Area Connection 4 (LAN Port) and Local Area Connection 5 (Gateway board) the only members
of the bridge
• Disable Local Area Connection 6
Now all network configuration settings should be made on the network bridge only. The SBA is ready for de
-
ployment after a final reboot.
2.5 Stainless steel box - Restore to factory settings
At the front as well as at the back of the case of the version for BRI‘s, there is one micro button each:
Table 2.3: Button on the stainless steel box
Micro button
Resulting function
Description
Micro button front
Hardware Reset
reboot system
Micro button rear
Software Reset
reset configuration parameters Function is deactivated one minute after
booting is completed (signaled by blinking diodes)
Reinstalling the software
Should OfficeMaster Gate (in the stainless steel version with 4 BRI) stop working properly, a recovery can be
done with newer versions of the product (February 2011 onwards, distinguishable by the USB port on the side). To
do this, the Gateway needs to be disconnected from the power supply and the recovery stick from the bottom of the
case has to be plugged into the USB port. Afterwards, reconnect the Gateway to the power supply. Turn off the Gate
-
way after roughly 30mins and remove the stick. When used afterwards, make sure a backup of the configuration is
loaded and, if needed, an update of the firmware is made.
Содержание OfficeMaster Gate
Страница 14: ...Chapter 2 OfficeMaster Gate Ferrari electronic AG Installation...
Страница 22: ...Chapter 3 OfficeMaster Gate Ferrari electronic AG Configuration...
Страница 70: ...Chapter 4 OfficeMaster Gate Ferrari electronic AG Advanced Configuration...
Страница 80: ...Chapter 5 OfficeMaster Gate Ferrari electronic AG...
Страница 90: ...Chapter 7 OfficeMaster Gate Ferrari electronic AG Appendix...
Страница 91: ...ii www ferrari electronic de Appendix A List of Abbreviations...
Страница 103: ...Chapter 6 OfficeMaster Gate Ferrari electronic AG Worth knowing...