background image

RX3C

Cavo centrale 

(bianco) RX3

RX3C

Central cable 

(white) RX3

RX3C

RX4M

Calza RX4

RX4M

RX4 sock

RX4M

RX4C

Cavo centrale 
(bianco) RX4

RX4C

Central cable 
(white) RX4

RX4C

TX Morsetto M3

(Cavo centrale rosso)

TX terminal-board M3 

(red central cable)

TX1M

Calza  TX1

TX1M

TX1 sock

TX1M

TX1C

Cavo centrale 

(Rosso) TX1

TX1C

Central cable 

(red) TX1

TX1C

TX2M

Calza  TX2

TX2M

TX 2 sock

TX2M

TX2C

Cavo centrale 
(Rosso)TX2

TX2C

Central cable 
(red) TX2

TX2C

TX3M

Calza  TX3

TX3M

TX3 sock

TX3M

TX3C

Cavo centrale 

(Rosso) TX3

TX3C

Central cable 

(red) TX3

TX3C

TX4M

Calza  TX4

TX4M

TX 4 sock

TX4M

TX4C

Cavo centrale 
(Rosso)TX4

TX4C

Central cable 
(red) TX4

TX4C

Morsetto M4

M4 Terminal-board

-

Ingresso TEST 

polo positivo 

-

TEST input, 

positive pole

-

+

Ingresso TEST polo 

negativo

+

TEST input, 

negative pole

+

LEGENDA

LEGENDA

M1

Morsetto principale

M1

Main terminal board

M1

M2

Morsetto 
connessione cavi 

RX

M2

Terminal-board for 
connection RX cables

M2

M3

Morsetto 

connessione cavi 
TX

M3

Terminal-board for 

connection TX cables

M3

M4

Morsetto ingresso 
TEST centrale 

motore. Se la 
centrale motore non 

è dotata di TEST, 
non collegare

M4

Terminal-board input 
TEST engine control-

box. If the control-box 
of the engine has no 

TEST function, do not 
connect.

M4

S1

Dip switch per la 
selezione del 

numero di raggi 
utilizzati

S1

Dip-switches to select 
the number of used 

beams.

S1

Dip

1

Dip

2

Fascio 

Attivo

Dip

1

Dip

2

Active 

beam

Dip

1

Dip

2

Off

Off TX1-RX1

Off

Off

TX1-RX1

Off

Off

TX1-RX1

On

Off TX1-RX1

TX2-RX2

On

Off

TX1-RX1
TX2-RX2

On

Off

TX1-RX1
TX2-RX2

Off

On TX1-RX1

TX2-RX2
TX3-RX3

Off

On

TX1-RX1

TX2-RX2
TX3-RX3

Off

On

TX1-RX1

TX2-RX2
TX3-RX3

On

On TX1-RX1

TX2-RX2
TX3-RX3

TX4-RX4

On

On

TX1-RX1

TX2-RX2
TX3-RX3

TX4-RX4

On

On

TX1-RX1

TX2-RX2
TX3-RX3

TX4-RX4

J1

Selezione 12 o 24 V
12V : jumper chiuso

24V: jumper aperto

J1

Selecting 12 or 24 V

12V: jumper closed

24V: jumper open

J1

J2

Inserire se la 

centrale motore non 
è dotata di TEST 

J2

Insert if the engine 

control-box is not 
TEST function 

provided

J2

Ca

ble blanc

central RX3

 

blindage 

RX4

Cable blanc

central 

 RX4

TX 

Bornier 

M3

(Ca

ble rouge central

)

blindage

 TX1

.

cable rouge 

central TX1.

blindageTX2.

cable rouge 

central TX2.

blindageTX3.

cable rouge 

central TX3.

blindage TX4.

cable rouge 

central TX4.

Bornier

 M4

entrée

 TEST 

pôle 

positif

entrée TEST pôle 

negatif

LÉGENDE

bornier principal

bornier connexion 

cables RX

bornier connexion 

cables TX

Bornier d'entrée TEST 

centrale du moteur. Si 

l'unité de contrôle du 

moteur n'est pas 

équipée de TEST, ne 

pas connecter.

Dip 

pour la selection

du nombre des 

rayons utilisés.

 

Sele

ction 

12  o

24  V

 

12V:

 

jumper

  fermé 

24V: jumper 

ouvert

à inserer si le cadre 

moteur n'a pas le 

TEST

Содержание NoTouch 2

Страница 1: ...eams which is typically used for garage doors The three rays control the three exposed sides of the door The device also has a central input TEST which allows in case the engine control box is provided with TEST safeties to control the connection between NOTOUCH2 and the engine control box CARATTERISTICHE TECNICHE TECHNICAL FEATURES Alimentazione 12 24V ac dc Power supply 12 24 V ac dc Consumo 1 f...

Страница 2: ...m Common Relay Com commun relais NC Normalmente chiuso rele NC N C Relay NC NF relais NO Normalmente aperto rele NO N O Relay NO relais RX Morsetto M2 Cavo centrale bianco RX terminal board M2 white central cable RX1M Calza RX1 RX1M RX1 sock RX1M RX1C Cavo centrale bianco RX1 RX1C Central cable white RX1 RX1C RX2M Calza RX2 RX2M RX 2 sock RX2M RX2C Cavo centrale bianco RX2 RX2C Central cable white...

Страница 3: ... Dip switch per la selezione del numero di raggi utilizzati S1 Dip switches to select the number of used beams S1 Dip 1 Dip 2 Fascio Attivo Dip 1 Dip 2 Active beam Dip 1 Dip 2 Off Off TX1 RX1 Off Off TX1 RX1 Off Off TX1 RX1 On Off TX1 RX1 TX2 RX2 On Off TX1 RX1 TX2 RX2 On Off TX1 RX1 TX2 RX2 Off On TX1 RX1 TX2 RX2 TX3 RX3 Off On TX1 RX1 TX2 RX2 TX3 RX3 Off On TX1 RX1 TX2 RX2 TX3 RX3 On On TX1 RX1 ...

Страница 4: ...s B LED to turn off Attenzione Attention Per il rispetto delle normative è necessario che la centrale motore abbia il TEST sicurezze in modo da controllare anche il collegamento tra il NOTOUCH2 e la centrale motore For the compliance of normatives is necessary that the motor control box has the safeties TEST so as to control also the connection between the motor control box and NOTOUCH2 Si la LED ...

Страница 5: ...Soyez prudent lors de la connexion des câbles en respectant la polarité en insérant le blindage sur le pôle marqué M et le pôle central du câble sur le pôle marqué C Réglez le DIP S1 en fonction du nombre de faisceaux que vous souhaitez contrôler en suivant le tableau écrit dans la légende dans les pages précédentes Centrage du Notouch2 à 3 faisceaux Pour un centrage rapide des photocellules posit...

Страница 6: ...icate to the engine control box the detected obstacle If the engine contro box is equipped with test function and is therefore present the connection to terminal M4 for each test request by the engine control box will follow the switching of the relay So to test the last part of the link between NoTouch 2 and engine control box To avoid false alarms verify that the optical alignment between TX and...

Страница 7: ... be performed by qualified persons The manufacturer is not responsible for damage or injury caused by improper installation of the system or due to an incorrect risk evaluation carried out during the installation Product at low voltage Do not apply HIGH VOLTAGE For installation refer to the current regulations in terms of electrical and mechanical safety Via Chienti 10 20052 Monza Mi Italy Tel 39 ...

Страница 8: ......

Страница 9: ......

Отзывы: