Ferono FK90E3 Скачать руководство пользователя страница 6

FOR THREE PHASES UNIT

: When the unit is working at the above b. situation, press “HEAT” in the remote

controller, receiver receives the signal with the sound of “beep” and switch cool mode to heating mode at low
power. Meanwhile there is a Red light display in the receiver. Press “HEAT” button again, the unit will switch low
power to middle power. Meanwhile there is TWO Red lights display in the receiver. Press “HEAT” button again,
the unit will switch middle power to high power. Meanwhile there is THREE Red lights display in the receiver.
Press “HEAT” button again, the unit will switch heating mode to cool mode and the red lights display change to
green light in the receiver. So FOR THREE PHASES MODEL when the unit is working at cool mode, press
“HEAT” button can switch air curtain working under the cycle of heating low power, heating middle power,
heating high power or cool mode. 

d. When the unit works at cool mode, press “ON/OFF” button to turn OFF the unit. 
e. When the unit works at heating mode, press “ON/OFF” button, receiver receives the signal with the sound of “beep”

and switch to cool mode at high speed, the indication light turns to green flicker light. The unit will continue to work
in cool mode for 3 minutes and then stop. (This is to ensure the heater is been cooled down and has 3 minutes delay
stop). 

7.2. Controlled by the control panel in the unit is the same function as 7.1. 
7.3. Overheat protection: 

     When   the   air   curtain   works   at   heating   mode,   there   is   overheat   protection.   When   the   heater   temperature   is

overheating, heating mode will stop and switch to cool mode automatic, at the same time the indication light
change to green light. When the temperature drop down to a certain temperature, if want the unit to work at heating
mode, press “HEAT” button to continue to work heating mode. 

 

8

CAUTIONS 

1)

Turn off the interrupter or disconnect the plug for any maintenance service. 

2)

Turn off the interrupter or disconnect the plug in case of a non product use. 

3)

Make sure that the product provides a ground wire. 

4)

The pictures shown on this manual are illustrative only.

5)

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental

capabilities,   or   lack   of   experience   and   knowledge,   unless   they   have   been   given   supervision   or   instruction
concerning use of the appliance by a person responsible for their safety. 

6)

Children should be supervised to ensure that they do not play with the appliance. 

7)

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified

persons in order to avoid a hazard. 

9

ATTENTION 

 

a)

Use the unit at the rated voltage and frequency indicated on the nameplate.

b)

Do not wet the product electrical components. 

c)

Never use petrol, benzene, thinners or any other such chemical to clean the unit. 

d)

Routine maintenance must be done every year. 

Содержание FK90E3

Страница 1: ...USER MANUAL Air curtain with an electric heater Models FK90E3 FK120E3 FK150E3 FK200E3 FK90E FK120E FK150E FK200E www ferono com info ferono com ...

Страница 2: ...of air curtain Note code of improved design of Y type of wireless remote control D type of AC electrical heating D single phase 3D three phases 3 IDENTIFICATION INSTALLATION DIMENSIONS 4 INSTALLATION CAUTION Must follow the following requests when installing air curtain 4 1 Please install the unit in a sturdy place to avoid the shaking and ensure its security because it maybe causes the wall becom...

Страница 3: ...exposed to excessive steam explosive gas or corrosive gas 5 INSTALLATION A Installing on the concrete wall 5 1 1 Removed the mounting plate Unclamping the fixed screws on the back of main body to removed the mounting plate MO UNTIN G PIATE FIXI NG SCRE W 5 1 2 Fix the bolts in the proper position Fix the position with the mounting plate and pour cement into the bolt holes CONC RETE 13 15mm 70mm φ4...

Страница 4: ... the ceiling brackets and ensure safe fixing use the bolts attached to the ceiling brackets as Fig Using the ceiling brackets to hang from the ceiling the position of mounting plate can be adjusted in the limit of 100mm 5 3 4 Do the same as step A to install the main body 5 2 1 Fix the mounting plate in the proper positions with tapping screw MOODEN SCREW MOUN TING PI ATE 5 2 2 Same as the step 5 ...

Страница 5: ...Meanwhile there is a green light display in the receiver Press COOL button again the unit will switch low speed to high speed So when the unit is working at cool mode press COOL button can switch air curtain working under the cycle of Low or High speed c FOR SINGLE PHASE UNIT When the unit is working at the above b situation press HEAT in the remote controller receiver receives the signal with the...

Страница 6: ...ntrol panel in the unit is the same function as 7 1 7 3 Overheat protection When the air curtain works at heating mode there is overheat protection When the heater temperature is overheating heating mode will stop and switch to cool mode automatic at the same time the indication light change to green light When the temperature drop down to a certain temperature if want the unit to work at heating ...

Страница 7: ...e warranty is valid only with invoice Air curtain model Serial number Sale date Invoice number Service sign and stamp Instalation date Instalation adress Electrical permission number Service sign and stamp CONFIRMATION OF INSTALLATION BY AUTHORIZED SERVICE ...

Страница 8: ......

Отзывы: