6
、
HEATING MODEL TECHNICAL PARAMETER
POWER
ITEM
SINGLE PHASE
( 230V~
,
MAIN LINE:L
、
N)
THREE PHASES
( 400V~ MAIN LINE:A
、
B
、
C
、
N)
HEATER
POWER
(
kW
)
3
4
5
6
8
10
14
3
4
5
6
8
10
14
MAIN
LINE
(
mm
2
)
1.5
2.5
2.5
4.0
6.0
10
10
1.0
1.0
1.0
1.5
2.5
2.5
4.0
EARTH LINE
(mm
2
)
0.75
1.0
1.0
1.5
2.5
2.5
4.0
0.75
0.75
0.75
0.75
1.0
1.0
2.5
W
H
I
T
E
BLUE(BROWN/RED)
YELLOW
c
MOTOR
ORANGE
(YELLOW)
B
L
A
C
K
Y
E
L
L
O
W
-
G
R
E
E
N
RECEIVER
IC
HEATER
HEATER
B C
N A
PN
THERMAL CUT-OUT
THERMAL CUT-OUT
THERMAL CUT-OUT
on
com
1
2
com
on
on
com
3
I/O
RECEIVER
BROWN
BLUE
WHITE
GREY
YELLOW-GREEN
W
H
I
T
E
BLUE(BROWN/RED)
YELLOW
c
MOTOR
ORANGE
(YELLOW)
B
L
A
C
K
Y
E
L
L
O
W
-
G
R
E
E
N
RECEIVER
IC
HEATER
HEATER
L
N
PN
THERMAL CUT-OUT
THERMAL CUT-OUT
THERMAL CUT-OUT
on
com
1
2
com
on
on
com
3
I/O
RECEIVER
BROWN
BLUE
WHITE
GREY
YELLOW-GREEN
7
、
OPERATION
7.1. Controlled by remote controller
a. Press “ON/OFF” button to turn ON the unit. Main receiver receives the signal with the sound of “beep” to start
working with the green light in cool mode at high speed “H”. Press “ON/OFF” button again to turn OFF.
b. When the unit is working at the above a. situation, press “COOL” button in the Remote controller, receiver receives
the signal with the sound of “beep” and switch high speed to low speed “L”. Meanwhile there is a green light
display in the receiver. Press “COOL” button again, the unit will switch low speed to high speed. So when the unit
is working at cool mode, press “COOL” button can switch air curtain working under the cycle of Low or High
speed.
c. FOR SINGLE PHASE UNIT
: When the unit is working at the above b. situation, press “HEAT” in the remote
controller, receiver receives the signal with the sound of “beep” and switch cool mode to heating mode at low
power. Meanwhile there is a Red light display in the receiver. Press “HEAT” button again, the unit will switch low
power to high power. Meanwhile there is TWO Red lights display in the receiver. Press “HEAT” button again, the
unit will switch heating mode to cool mode and the red lights display change to green light in the receiver. So when
the unit is working at cool mode, press “HEAT” button can switch air curtain working under the cycle of heating
low power, heating high power or cool mode.
LINE SIZE
FK90E3
FK120E3
FK150E3
FK200E3
FK90E
FK120E
FK150E
FK200E
160
200
230
350
160
200
230
350
2
2.7
3.3
4.6
3
4
5
7
4
5.3
6.7
9.4
6
8
10
14
6
8
10
14
-
-
-
-
115
115
400/50
230/50
35-45 8.5
35-45 8.5
1000
1500
1900
2800
1000
1500
1900
2800
55-57
56-58
57-59
59-61
55-57
56-58
57-59
59-61
14.5
17
22
26
14.5
17
22
26
MODEL
Diam.
Of
Wheel
(mm)
Voltage
/Freq.
(V
〜
/Hz)
Motor
Power
(W)
Heater power
(KW)
I
II
III
Temp.
(K)
Max.air
speed
(m/s)
Air
volume
(m3/h)
Noise
(dB)
Net
weight
(Kg)
Содержание FK90E3