Ferono FK90E3 Скачать руководство пользователя страница 3

4.3 Don’t install the unit too low, no less than 2.3 

meters from the ground.

4.4 When the entrance is wider than the unit,

it is recommended to install two or more
units in parallel. In this case, provide 20-
40mm gaps between the units.

4.5 Don’t allow gaps between the unit and the 

wall. When hanging it from the ceiling, using 
the enclosed ceiling brackets.

4.6 Don’t install the unit in a place where it is

splashed by water, exposed to excessive
steam, explosive gas or corrosive gas.

5

INSTALLATION

A

Installing on the concrete wall:

5.1.1 Removed the mounting plate

Unclamping the fixed screws on the back of 
main body to removed the mounting plate.

MO UNTIN G PIATE

FIXI NG SC RE W

5.1.2 Fix the bolts in the proper position (Fix

the position with the mounting plate and
pour cement into the bolt holes.)

CONC RETE

13-15mm

 70mm

φ

4

0

-

5

0

m

m

5.1.3 When the cement has freeze, fit the mounting

plate (use the washer and nut according to the
following)

5.1.4 Install the main body

 Set the main body onto the upper end of the

mounting plate and clamp it as shown.

Содержание FK90E3

Страница 1: ...USER MANUAL Air curtain with an electric heater Models FK90E3 FK120E3 FK150E3 FK200E3 FK90E FK120E FK150E FK200E www ferono com info ferono com ...

Страница 2: ...of air curtain Note code of improved design of Y type of wireless remote control D type of AC electrical heating D single phase 3D three phases 3 IDENTIFICATION INSTALLATION DIMENSIONS 4 INSTALLATION CAUTION Must follow the following requests when installing air curtain 4 1 Please install the unit in a sturdy place to avoid the shaking and ensure its security because it maybe causes the wall becom...

Страница 3: ...exposed to excessive steam explosive gas or corrosive gas 5 INSTALLATION A Installing on the concrete wall 5 1 1 Removed the mounting plate Unclamping the fixed screws on the back of main body to removed the mounting plate MO UNTIN G PIATE FIXI NG SCRE W 5 1 2 Fix the bolts in the proper position Fix the position with the mounting plate and pour cement into the bolt holes CONC RETE 13 15mm 70mm φ4...

Страница 4: ... the ceiling brackets and ensure safe fixing use the bolts attached to the ceiling brackets as Fig Using the ceiling brackets to hang from the ceiling the position of mounting plate can be adjusted in the limit of 100mm 5 3 4 Do the same as step A to install the main body 5 2 1 Fix the mounting plate in the proper positions with tapping screw MOODEN SCREW MOUN TING PI ATE 5 2 2 Same as the step 5 ...

Страница 5: ...Meanwhile there is a green light display in the receiver Press COOL button again the unit will switch low speed to high speed So when the unit is working at cool mode press COOL button can switch air curtain working under the cycle of Low or High speed c FOR SINGLE PHASE UNIT When the unit is working at the above b situation press HEAT in the remote controller receiver receives the signal with the...

Страница 6: ...ntrol panel in the unit is the same function as 7 1 7 3 Overheat protection When the air curtain works at heating mode there is overheat protection When the heater temperature is overheating heating mode will stop and switch to cool mode automatic at the same time the indication light change to green light When the temperature drop down to a certain temperature if want the unit to work at heating ...

Страница 7: ...e warranty is valid only with invoice Air curtain model Serial number Sale date Invoice number Service sign and stamp Instalation date Instalation adress Electrical permission number Service sign and stamp CONFIRMATION OF INSTALLATION BY AUTHORIZED SERVICE ...

Страница 8: ......

Отзывы: