EVENTS AND SOLUTIONS TABLE
P1
P2
Volume control
potentiometers
Regulate volumen potentiometers P1 and P2 in the
amplifier.
SYMPTOM
POINTS TO CHECK
Not heard from outdoor panel, but
heard from the telephone.
Regulate the volume potentiometer P1 in the
amplifier.
Cable nº 1 of installation cut, (door open mechanism
does not work).
Cable nº 2 of installation cut.
Cables nº 1 and nº 2 of installation short circuited,
(in this case the acoustic call-to-dwelling alert heard
at the panel does not work ).
Cables nº 1 and nº 3 of installation short circuited,
(the door opener is permanently activated).
Not heard from telephone but
heard from outdoor panel.
Regulate the volume potentiometer P2 in the
amplifier.
Cable nº 6 of installation cut.
Cable nº 3 of installation cut, (and call does not work).
Cables nº 3 and nº 6 of installation short circuited.
Acoustic coupling in panel and
telephone.
Telephone does not receive call.
Cable nº 4 of installation cut or loose.
Cable Cp of amplifier cut or loose.
Door opener malfunction.
Supply failure: card slot does not light up.
Insufficient wiring section: card slot illumination dims
when door open button is pressed.
Door opener is always activated.
Cables nº 1 and nº 3 of the installation short circuited.
When receiver is picked up door
opener is activated.
Cables nº 1 and nº 6 of the installation short circuited.
Keyboard does not work.
Check internal panel prewiring .