background image

 
 

INSTALLER MANUAL 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REF. 1445 KIN PANEL 

INSTALLER MANUAL 

 

Содержание MEET KIN 1445

Страница 1: ...1 INSTALLER MANUAL REF 1445 KIN PANEL INSTALLER MANUAL...

Страница 2: ...LECTR NICA applies a continuous improvement policy therefore it reserves the right to modify the contents of this document as well as the product features hereof at any time and without prior notice A...

Страница 3: ...13 RESTORE 24 2 14 LOG OUT 25 3 OPERATION 26 3 1 Icon functions 29 4 INSTALLATION 33 4 1 Flush box installation 33 4 2 Installation Guide Diagram 33 4 3 Connectors 34 4 4 Basic diagrams 35 4 5 Diagra...

Страница 4: ...ng their authorized Mifare identifier The door will open and release the lock The Mifare identifier data must be added through FERMAX MEET MANAGEMENT software Maximum 100 000 identifiers By means of t...

Страница 5: ...st be connected to the same LAN as the panel and configured with an IP address in the same range The KIN panel default IP address is 10 1 0 1 Type the IP address of the panel in the address bar of the...

Страница 6: ...E provides technical information regarding the equipment as a reference FERMAX KIN PANEL Device type FIRMWARE Version of the installed firmware DEVICE Type and panel number MAC Panel MAC number IP IP...

Страница 7: ...on TYPE selection GENERAL ENTRANCE PANEL Panel installed in one of the main entrances to a condominium DEVICE NUMBER Number assigned to the general entrance where this panel is installed 1 9000 In th...

Страница 8: ...ult value 1 ALPHANUMERIC KEYPAD Select this box if this panel will use alphanumeric call and unselect if it will use numbers only In the case of ALPHANUMERIC call the available characters are A to H T...

Страница 9: ...es will start to ring SCREENSAVER Enable or disable screen saver of the panel The screensaver appears when the panel is idle and nobody is in front of it for 60 seconds Then and after 3 minutes the pa...

Страница 10: ...in this case GMT is usable only when the time is automatically taken from internet or FERMAX MANAGEMENT SOFTWARE Date and time cannot be saved after power loss unless there were internet or managemen...

Страница 11: ...of the conflicting device Both devices will not work properly until this issue is resolved 2 4 ACCESS This section allows some programming related to the access control functionality of the panel DOO...

Страница 12: ...he card of the residents can be added afterwards To program user cards present the admin master card previously created on the card reader The panel will enter in cards program mode All the cards pres...

Страница 13: ...fault 5 0 in this version LIVENESS DETECTION Enable or disabled LIVENESS DETECTION function SIMILARITY High medium and low options Default is low NOTES MEET panel face recognition function is based on...

Страница 14: ...de different view angles from the door or related areas NUMBER OF CAMS Select up to 4 different cameras o CAMERA 1 2 3 and 4 IP camera name o URL rtsp user password Ip_adress_of_camera user password f...

Страница 15: ...t function to smartphone through the FERMAX MEET ME server is used ENABLE SIP Select this box to enable SIP functions SIP SERVER Use the FERMAX MEET server sip sip fermax com DOMAIN Indicate the serve...

Страница 16: ...he sip SERVER address Format sip IP_SERVER DOMAIN domain of the SIP server or IP address OUTBOUND Not necessary Leave it in blank STUN IP domain of the SIP server STUN PORT Used for the configuration...

Страница 17: ...or cloud SIP TRUNK SERVER The panel call can be diverted to user s mobile phone or land line telephone through a voice gateway ENABLE SIP TRUNK Enable or disable SIP trunk function URL URL of the devi...

Страница 18: ...r third party SIP devices as well using SIP protocol instead of FERMAX MEET protocol A CSV file containing the associated number and the information of the diverted device or devices must be updated i...

Страница 19: ...identification user that the called device has been programmed in the SIP server and IP_SIP_SERVER is the SIP server IP address d It is also possible to assign multiple and different divert formats t...

Страница 20: ...e it is possible to use the call pushbutton in the panel to directly call to a specific device monitor SIP telephone smartphone running FERMAX MEET ME APP URL Indicate the device that has to receive t...

Страница 21: ...4 Use the following cells A2 A3 A4 etc to fill in the data of apartment name ad user s name with the format Apartment number Name 5 Once the table has been finished save it and import to the panel For...

Страница 22: ...CSV file in the notepad with the desired alphabet Latin Chinese Russian Cyrillic Arabic 3 Save the file as CSV all files UTF 8 4 From the panel s webserver import this file and wait for the message f...

Страница 23: ...s no limit on its length Finally select SAVE NOTE Make a note of the new PIN at your convenience If you lose or forget your PIN you should contact FERMAX s Technical Department to receive instructions...

Страница 24: ...1 DEVICE 1 APARTMENT 101 for 1W panel operation LANGUAGE ENGLISH VIDEO RESOLUTION 640 x 480 INSTALLER PASSWORD 123456 NETWORK IP 10 1 0 1 MASK 255 0 0 0 GATEWAY 10 254 0 1 DNS 8 8 8 8 SOFTWARE IP 10 0...

Страница 25: ...25 2 14 LOG OUT Use this functionality if you want to end your working session with this panel The panel will request access credentials again in the case of new access via web server...

Страница 26: ...the programming settings the call keypad can be numerical alphanumerical or individual It is also possible to select one of the available function icons at the bottom of the screen These icons must be...

Страница 27: ...ts these letters to numbers A to 1 B to 2 etc For example dialling 80C the called monitor is 803 It is also possible to select and use the available icon functions call concierges face recognition etc...

Страница 28: ...he panel is configured as a 1W KEPAD it is not possible to access the information screen from the panel since with that configuration the panel does not allow to dial 9999 it only admits calls to the...

Страница 29: ...s available use the horizontal scroll over the icons to make visible the hidden ones The utility of each icon is explained below Tap on the corresponding icon to use the associated function HELP icon...

Страница 30: ...s also possible to call other concierges different than the ones with icon dialling the corresponding concierge number as same as a call to an apartment FACE RECOGNITION icon Users can be identified b...

Страница 31: ...required See WEB BROWSER PROGRAMMING section for further details GUEST CODE icon This option allows users to open the door by means of entering a PIN code that has been provided to him for example to...

Страница 32: ...SS PIN code Length of ACCESS PIN could be between 4 to 6 digits The panel admits up to 8 different ACCESS PIN that must be programmed by the installer See WEB BROWSER PROGRAMMING section for further d...

Страница 33: ...anel is stuck in then move the panel to the flush box 4 Move the slider of the panel and fix the two screws When installing pay attention to the reservation of the 2 cm space around the door to move t...

Страница 34: ...r button F Input for fire alarm block doors unlock contacts DS Connection for door opened sensor RS485 Output for Ref 1491 Ref 9545 MEET LIFT Control Gateway Ref 1494 Guest code or Ref 1490 External R...

Страница 35: ...t power the panel and the electric lock from the same power supply The panel has an internal tamper button If the panel is separated from the wall an alarm is triggered in the panel concierge and FERM...

Страница 36: ...decoder RS485 address need be set to number 2 factory defaults is 2 4 6 Diagram installation of the GUEST CODE Module Ref 1494 4 7 Diagram installation of the lift control system Ref 9545 This instal...

Страница 37: ...ing resistor is connected automatically when temperature is below 20 C Display specifications Size 10 1 inch Format 16 9 Resolution 1024 x 600 Camera specifications Resolution 1280 H x 720 V Visual an...

Страница 38: ...ate file The firmware update is performed via the The procedure for updating the firmware with the corresponding update file is as follows It is possible to update several panels at the same time sele...

Страница 39: ...and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that inte...

Отзывы: