Pag 38
Answer a call from an indoor panel (panel decoder )
1.
Someone calls from a panel, pressing the "PANIC"
key. The Guard Unit starts to "beep", indicating that a call
is coming in.
The display indicates the number of the panel and block
the call is made from with a "D" + three digits .
If the call from the panel is made from the same block
(where the panel is connected), the display indicates only
the panel number.
Example: The call is from panel nº 2 in block nº 4 (the
panel is connected in another block).
2.
To answer the call, pick up the handset and press the
BELL
key
The display indicates PANEL-GUARD UNIT communi-
cation
.
- The call is from panel nº 2 in the block where the
panel is connected.
C
P
M :01/01
04 D002 18:15
D :01/01
D002 18:20
M
04 D002 18:15
4.
To end communication with the panel, press the
Hash
key
3.
If you want to open the door, press the
Door Lock
key
while PANEL-CONCIERGE communication is in progress.
Содержание MDS Digital Guard Unit
Страница 1: ...Central de Conserjer a Guard Unit...