4
DUOX PLUS CITYLINE WIFI VEO VIDEO KIT
WIRING DIAGRAMS
4. CAMERA FOCUS / LOCK RELEASE ACTIVATION TIME*
To adjust the camera image or adjsut the lock-release activation time.
* See Voice assisted configuration in button panels cod. 970048. Instructions included with this
equipment.
- (i) For the 12Vdc lock-release and max. consumption 250mA, powered by the amplifier.
3. ENCODING PANELS*
Whenever there is more than one panel, you must program the number of panels.
TECHNICAL FEATURES
PANEL VALUES
Lock-release activation time
01...99 sec. (Default: 03)
Exit button activation time
00...99 sec. (Default: 06) / (deactivated: 00)
Panel type
sub-block/block/general entrance. (Default: block)
Panel number
0..9 (by default: 00)
MASTER panel
PANEL TECHNICAL CHARACTERISTICS
Power Supply
18-24 Vdc
Standby Consumption
2,86 W
Audio active consumption
6,30 (max) W
Audio Power in Residence - Entry Panel Direction
1 W
Audio Power in Entry Panel - Residence Direction
0.15 W
Operating temperature
[-25º , +70ºC] / [-13º, 158ºF]
Volume can be Regulated in Both Directions.
MONITOR TECHNICAL CHARACTERISTICS
(OSD TFT 4,3” Screen)
Power supply
18-24 Vdc
Standby consumption
1,3 W
Maximum consumption
5,6 W
Operating temperature
[-5º , +40ºC] / [23º, 104ºF]
SECTIONS-DISTANCES TABLE
1
250
1
200
1
100
2
200
250
2
120
200
2
50
80
3
150
3
70
3
30
OUTPUT
INPUT
REF. 4825
100-240V ; 1,2 A
50-60 Hz
PROTEGIDO POR FUSIBLE ELECTRÓNICO
ELECTRONIC FUSE PROTECTED
24 V ; 2,5 A
ON
OVERLOAD
ALIMENTADOR - POWER SUPPLY
B B
POWER BUS
PREV BUS
NO VOLTAGE / SIN TENSIÓN
PAS DE TENSION / NICHT SPANNUNG
N
L
Vac
B B
Ref. 4825
OUTPUT
INPUT
REF. 4825
100-240V ; 1,2 A
50-60 Hz
PROTEGIDO POR FUSIBLE ELECTRÓNICO
ELECTRONIC FUSE PROTECTED
24 V ; 2,5 A
ON
OVERLOAD
ALIMENTADOR - POWER SUPPLY
B B
POWER BUS
PREV BUS
NO VOLTAGE / SIN TENSIÓN
PAS DE TENSION / NICHT SPANNUNG
N
L
Vac
B B
Ref. 4825
SECTION
CABLE
TERMINALS per home
without additional power
source
Maximum distance (A) Source
/ Filter up to Panel (Panel-Lock
release) (i)
Maximum distance (B)
Source/Filter up to Panel
Furthest terminal
Distance section table - VIDEO KIT INSTALLATION