Supply the panel by means of
a FERMAX Ref. 4813 (18 Vdc
2A) power supply
Use a power supply adapted
to the electric lock voltage &
current. Do not power the
panel and the electric lock
from the same power supply.
This panel has an internal tamper button. If the panel is separated from the wall, an alarm is
triggered in the panel, concierge and FERMAX MANAGENEMN SYSTEM (if exists).
4.4
Basic diagrams
4.5
Installation of the 4 RELAY MODULE REF. 1491
This module is necessary if you want to use the facility of activating from the monitors additional
relays (up to 4), for example to activate additional doors or gates.
NOTE:
The 1491 module need be connected to the PANEL No.1 in the block. The decoder RS485 address
need be set to number 2 (factory defaults is 2). If you need read and write the address 1491, please
run the software MODBUS RTU ADDRESS CONFIG TOOL.exe.