SOFTWARE PIN:
PIN ACCESS code for the Management Software control. The default setting
is 123456. Indicate the corresponding parameters and click on SAVE to confirm.
NOTE:
The MEET system uses static IP addressing. This ensures that each device has a unique IP address
in the same installation.
If a device has an IP address already assigned to another device on the network, an "IP CONFLICT"
prompt will appear in the TFT display of the panel, along with the MAC of the conflicting device.
Both devices will not work properly until this issue is resolved.
2.4
ACCESS
This section allows some programming related to the access control functionality of the panel.
DOOR RELAY TIME
: Time for lock-release relay remains active (1-9 s optional).
OPEN DOOR DELAY
: The time that the open-door command has be sent and the relay is not
activated. The relay will active after the DOOR DELAY TIME be set, Open door relay is useful
when the door is not close the panel. (option 0-9 s)
DOOR OPEN ALARM:
An alarm will trigger if the door keeps opened after the programmed
DOOR ALARM time. Options: disable, 30s. 60s. 120s, 180s and 250s.
DOOR FORCED ALARM:
An alarm will trigger if an abnormal way opens the door has been
detected, for example because there has not been any previous “open the door” command.