11
EXT. UNLOCK
: Only available in panel programmed as PANEL 1. It activates or deactivates the
additional relay performance.
A module Ref. 1491 (4 relay module) must be connected to the RS485 port of the panel No.1.
See INSTALLATION section for further details.
o
1-4 DOOR RELAY TIME
: Time that the corresponding additional door relay keeps
active (1-9s optional).
o
1-4 OPEN DOOR DELAY
: The time that the open-door command has be sent and the
relay is not activated. The relay will active after the DOOR DELAY TIME be set, Open
door relay is useful when the door is not close the panel. (option 0-9 s).
ADMIN CARD:
Master card registered to enrol additional prox cards. When there is no
management software enter 0000 if you do not know the ID of the admin card. The first prox
card detected by the reader will act as admin/master card the card of resident can be added
afterwards. If this method is used, register the resident proximity id numbers on the cards.
DISARM BY CARD
: When an already programmed user card is presented to the reader, and it
has been previously assigned to a monitor, the alarm system of the corresponding apartment
will change to HOME mode.
GUEST CODE:
Guest code function can be enabled or disable. The panel need to be connected
with a module Ref. 1494 to a third-party Access Control System. See INSTALLATION section.
WIEGAND
Protocol used for Wiegand transmission (BURST or 26 BITS). Enter available
parameter depending on the third-party Access Control System
FACILITY
: Enter available parameter depending on the third-party Access Control System.
ACCESS PIN
: To enable or disable the activation of the relay for ACCES PIN code.
UP to 8 different PIN codes per panel. PIN length between 4 to 6 digits.
2.5
FACE RECOGNITION
Use this setting to enable or disable the FACE RECONGNITION function of the panel.
The FERMAX MANAGEMENT SOFTVARE V01.05 is required for programming and managing the
photos of the authorized faces. System supports up to 6.000 faces