![Fenix EPC1200 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/fenix/epc1200/epc1200_operation-manual_4008813028.webp)
EPC1200 SERIES OPERATION MANUAL
28/56
LF
[Name]
Print and line feed
[Format] ASCII
LF
Hex 0A
Decimal
10
[Description]
Prints the data in the print buffer and feeds one line, based on the current line spacing.
[Note]
This command sets the print position to the beginning of the line.
[Reference]
ESC 2
,
ESC 3
.
CR
[Name]
Print and carriage return
[Format] ASCII
CR
Hex
0D
Decimal
13
[Description]
When automatic line feed is enabled, this command operates the same as
LF
; when
automatic line feed is disabled, this command is ignored.
[Notes]
•
This command is set at the start-up, via the PROGRAMMING MODE (See point
3.6.2- PROGRAMMING MODE).
•
Sets the print starting position to the beginning of the line.
[Reference]
LF
DLE EOT n
[Name]
Real-time status transmission
[Format]
ASCII
DLE EOT
n
Hex
10 04
n
Decimal 16
04
n
[Range] 1
≤
n
≤
4
[Description] Transmits the selected printer status specified by
n
in real-time, according to the
following parameters:
n
= 1: Transmit printer status
n
= 2: Transmit offline status
n
= 3: Transmit error status
n
= 4: Continuous paper sensor status
n = 5: Paper sensor status
n = 100: Low byte (BL) of thermal head temperature
n = 101: High byte (BH) of thermal head temperature
[Notes]
•
The status is transmitted whenever the data sequence 16, 04, n (1
≤
n
≤
5) is
received.
•
The printer transmits the current status. Each status item is represented by one
byte.
•
The printer transmits the status without confirming whether the host computer can
receive data (in serial interface).
•
The printer executes this command upon receiving it.
•
This command is executed even when the printer is offline, the receiver buffer is
full, or there is an error status with a serial interface model.
•
If a not recovery error occurred, the bit 2 in the Printer Status (
n
=1) will be
indeterminate.
•
Thermal head temperature (ºC) is transmitted in two bytes and multiplied x 10. For
instance, if BL = 35H and BH = 02H, head temperature is (235H): 565/10 = 56.5ºC
n
= 1:
Printer status
Bit OFF/ON
Function
0
OFF
Not used. Fixed to OFF
1
ON
Not used. Fixed to ON
2
OFF
Not used. Fixed to OFF
3
OFF
Online
ON
Offline
4
ON
Not used. Fixed to ON