Caution 

 

• 

Only qualified persons may carry out work on the panel. Before launching such work, the panel must be 

  disconnected from the source of power. As it is made of fragile material, great care needs to be taken 
  during transport, manipulation and installation. 

  

Do not cover the panel in any situation.

 

The notice “NEZAKRÝVAT” (“DO NOT COVER”) notifies that any

 

  material covering the panel may cause a fire. Furniture must not be placed and curtains must not be 
  hung in front of the panel (see Fig. 1) and free circulation of air must be ensured. Dust must be removed 
  from the panel regularly, at least before the beginning of every heating season. Do not touch the panel 
  when in the bathtub or shower! 

  If small children have access to the area around the heater, install plastic corner protectors (accessories) 

  on the corners!  

 

The heater must not be used if the glass is damaged.  

 Be careful to choose the right type of anchoring element (wall plug), particularly when dealing with 

  plasterboard/gypsum fibreboard and porous concrete structures. If necessary, consult a specialised firm 
  or manufacturer about anchoring for example http://www.fischer.co.uk/Home.aspx 

 

Ceiling mounting temperatures  

  When mounted on the ceiling, higher temperatures occur on the ceiling behind the panels due to heat 
  accumulation. In continuous operation these can be about 45 Kelvin above the ambient temperature 
  (room temperature). The used fixing materials and ceiling materials shall meet both static 
  requirements and temperature-dependent requirements. 

 

WARNING:

 This heater 

isn´t fitted with a room temperature control device. Do not use this heater in

 

  small rooms if they are occupied by people who cannot leave the room by themselves unless permanent 
  supervision is provided. 

 This appliance can be used by children from the age of 8 and older, and persons with lower physical, 

  sensory or mental abilities or a lack of experience or knowledge providing they are under supervision or 
  have been trained in the use of the appliance in a safe manner and understand the possible danger. 
  Children may not play with the appliance. Cleaning and maintenance by the user must not be carried 
  out by children without supervision. Children under 3 years of age should be prevented from accessing 
  the appliance, unless they are constantly supervised. 

 Children from 3 to 8 years of age may switch the appliance on/off only if it is placed or installed in its 

  intended standard operating position and if they are under supervision or have been instructed in the 
  safe use of the appliance and if they understand the possible danger. Children from 3 to 8 years of age 
 

mustn´t insert the plug into the socket, control or clean the appliance or carry out maintenance that is

 

  to be done by the user. 
 

WARNING 

  Some  parts  of  this  product  may  become 

very  hot  and  cause  burns.  Special  attention  must  be 
paid  to  this  fact  in  the  presence  of  children  and 
handicapped persons!  

 

 

Fig. 1 

Содержание Ecosun GS 300

Страница 1: ...N798 R00 10 04 19 Ecosun GS Glass radiant panel Glas Strahlungsplatte Instructions for installation and use Montage und Bedienungsanleitung...

Страница 2: ...nt temperature room temperature The used fixing materials and ceiling materials shall meet both static requirements and temperature dependent requirements WARNING This heater isn t fitted with a room...

Страница 3: ...dowels and drive the screw in to protrude approx 5 mm Fig 8 Always hang the panel by all mounting slots Put the panel on the screws Clearance distances The distance between the bottom edge of the appl...

Страница 4: ...placed by the manufacturer or its service technicians Controlling the panel We recommend controlling this panel using an external room thermostat with a switch The room thermostat maintains the set ai...

Страница 5: ...es up evenly The more even the wet surface is the lower the risk of smudging Never use great pressure to wipe the glass dry If smudges appear on the glass anyway please repeat the procedure All produc...

Страница 6: ...terialien m ssen sowohl den statischen Erfordernissen wie auch den temperaturabh ngigen Anforderungen entsprechen WARNUNG Dieses Heizger t ist mit keiner Einrichtung zu Raumtemperatur berwachung ausge...

Страница 7: ...be einschrauben so dass sie nicht voll einge schraubt ist sondern ca 5 mm herausragt Abb 8 Die Platte immer mittels aller Verankerungen aufh ngen Abst nde Der Abstand der Unterkante des Verbrauchsger...

Страница 8: ...Hersteller oder seinem Servicetechniker zu ersetzen Bedienung der Platte Es wird empfohlen die Steuerung der Platte durch einen externen Raumthermostat mit Schalter durchzuf hren Der Raumthermostat er...

Страница 9: ...wenden Bei der Reinigung selbst keinen gro en Druck aus ben da sich die Glasoberfl che aufreiben kann oder sich Flecken auf ihr bilden k nnen Das Glas ist auf diese Weise so lange zu wischen bis das R...

Страница 10: ...495 304 Fax 420 584 495 303 Mail fenix fenixgroup cz Web www fenixgroup cz Produziert im Auftrag der Firma Christoph Krautheim Stra e 114 120 D 95100 Selb Tel 49 0 9287 500177 Fax 49 0 9287 500179 Mai...

Отзывы: