![Fenix 300 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/fenix/300/300_usage-and-installation-manual_3997374009.webp)
Installation Method
Installation position
After fixing the installation panel, you can use hang hook in the rear cover
of unit to hang the unit on the wall, as shown the left diagram.
After hanging the unit on the wall, lock the two anti-theft screws at the
bottom, as shown in the following figure.
12
13
500mm
Installation diagram
Installation location
Fix the installation panel to the wall, as shown in the below figure.
The installing method for the installation panel:
Choose the power connection mothod, then mark the position according
to the size of the paper pattern of the installation panel, drill the external
diameter
Φ
6 screw holes.
After drilling the screw holes, insert the rubber plug (attached with the unit)
in the screw hose.
Fix the installation panel with the mounting screws, as shown the below
figure.
Rear backinstallation panel
Anti-theft screw
Installation
panel
Power connection
Use a single-phase 220-240V power.
2
2
A single wire (cable core: between 2.0mm and 2.5mm ) is being used for
the power cable.
The first method of power line connection (pluggable):
At first, fix the socket near to the unit installation position.
Then, plug one end of the power cord into the unit, and plug the other end
into a socket on the wall.
Note! The power cord must be fixed in the wiring slot in the back of the unit.
※
When the unit is installed,
the power cord must be
clamped in the slot to
prevent the power cord
from falling off; otherwise
this may cause the unit
not to work.
Power socket
on the wall
near the unit
remove the screw before installation
100
Mounting screw
Mounting screw
Metal installation
panel
floor
anti-theft
screw hole
paper pattern of
installation panel
Anti-theft screw
floor
Recommended
installation heights
For men: 760mm
For women: 740 mm