![Fenix 300 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/fenix/300/300_usage-and-installation-manual_3997374010.webp)
15
Test Run
1
2
3
4
5
Test Run
Result
Step
Check
Check the voltage of power
supply
Turn the ground-fault circuit
breaker on
Turn the power switch on
Dry hands
Is single-phase alternating
current 220V
-
240V
(100-120V) used?
Does the power indicator light
up?
Is the air blowing?
Is the unit installed firmly?
Any vibration or strange noise?
Check the unit
*
Do not turn the unit power switch on with your hands inside.
*
If the self-check indicator in the display lights or is flashing, turn off the power switch off,
and turn the power back on when all the indicators go off (after 40 seconds).
Confirm ON
※
1
230mm
200mm
2
Power connection
The second method of power connection (cut-off plug)
Embed the switch box (with no cover) in
the installation position, used to connect
the power line (the combination of green
and yellow wires is ground wire).
If not using the switch box, the
power supply line will be squeezed
out of the unit body and cannot be
fixed firmly.
Power cord
(with ground
wire)
Cut off the plug of the
power cord
Remain about 30cm long power cord
connecting to the unit
14
3
230mm
230mm
After hanging the unit
on the wall, connect
the remaining power
cord to the power
socket on the wall
(below the unit).
Power connection
position (at the bottom
of unit)
Power socket on the
wall (below the unit)
Switch box
floor