14
11. TROUBLESHOOTING
In case the energizer is not working properly, try to solve it according to the following table.
Cause
Fault removal
Energizer does not work?
There is no signalling on the LED indicator.
The energizer is either manuály switched off, then
switched on. If it cannot be switched on, then
disconnect it from the fence systém, plug it into the
mains using an adapter and then switch the energizer
again. If the blue or purple LED is on, then the device
is fine. I fit is red, then the points see below. Otherwise,
the device is damaged (contact the seller) During using
battery and battery operated devices, observe the
correct connection of the poles.
Red flashes twice on the LED control.
The battery voltage drops below 12 V – replace the
battery with a charged one or connect an adapter.
Red flashes twice on the LED control and the
warning siren sounds.
The battery voltage drops below 11,6 V - replace the
battery with a charged one or connect an adapter.
Red flashes rapid and short on the LED control.
The voltage on the battery fell below 11,4 V and the
fence system was automatically switched off. This is to
protect the battery from deep discharge (destruction of
the battery). Replace the battery with a charged one or
connect an adapter – until the voltage on the battery
reaches at least 12,2 V, the red LED light will be on.
Lead-in or short circuit of supply lines of the fence
system.
Do not use conventional cables for supply lines.
Highvoltage cable is recommended.
Conductor has adverse properties (thin diameter,
high resistance).
Use high-quality conductor with low resistance and
larger diameter. Ensure high-quality correct connection
of conductors.
Low-quality earthing, too short earth rod,
corrosion, dry soil.
Add next rod, moisten.
Lead-in via growth near fence system.
Remove the growth (mow it).
Conductor on ground (for example break,
insufficient mechanical tension).
Repair fencing, use special connectors, stretch
conductor.
Too long fence system. Was correct accessories
used for given purpose?
Use accessories suitable for given length of fence
system and for animals – in case of need, consult
specialized salesman.
Insulator pierces, losses occur.
Replace defective and weather-worn insulators.
Conductor is connected via knot, insufficient
connection.
Use relevant special connectors for the conductor.