11. TROUBLESHOOTING

In case the energizer is not working properly, try to solve it according to the following table.

Cause

Fault removal

Energizer does not work?
There is no signalling on the LED indicator.

The energizer is either manuály switched off, then 
switched on. If it cannot be switched on, then 
disconnect it from the fence systém, plug it into the 
mains using an adapter and then switch the energizer 
again. If the blue or purple LED is on, then the device 
is fine. I fit is red, then the points see below. Otherwise, 
the device is damaged (contact the seller) During using 
battery and battery operated devices, observe the 
correct connection of the poles.

Red flashes twice on the LED control.

The battery voltage drops below 12 V – replace the 
battery with a charged one or connect an adapter.

Red flashes twice on the LED control and the 
warning siren sounds.

The battery voltage drops below 11,6 V - replace the 
battery with a charged one or connect an adapter.

Red flashes rapid and short on the LED control.

The voltage on the battery fell below 11,4 V and the 
fence system was automatically switched off. This is to 
protect the battery from deep discharge (destruction of 
the battery). Replace the battery with a charged one or 
connect an adapter – until the voltage on the battery 
reaches at least 12,2 V, the red LED light will be on.

Lead-in or short circuit of supply lines of the fence 
system.

Do not use conventional cables for supply lines. 
Highvoltage cable is recommended.

Conductor has adverse properties (thin diameter, 
high resistance).

Use high-quality conductor with low resistance and 
larger diameter. Ensure high-quality correct connection
of conductors.

Low-quality earthing, too short earth rod,  
corrosion, dry soil.

Add next rod, moisten.

Lead-in via growth near fence system.

Remove the growth (mow it).

Conductor on ground (for example break,  
insufficient mechanical tension).

Repair fencing, use special connectors, stretch  
conductor.

Too long fence system. Was correct accessories 
used for given purpose?

Use accessories suitable for given length of fence 
system and for animals – in case of need, consult 
specialized salesman.

Insulator pierces, losses occur.

Replace defective and weather-worn insulators.

Conductor is connected via knot, insufficient 
connection.

Use relevant special connectors for the conductor.

Содержание mini DUO MD03

Страница 1: ...30V 12V STORED ENERGY OUTPUT ENERGY OUTPUT VOLTAGE OUTPUT VOLTAGE500 SWITCHING ON OFF fencee miniDUOMD03 0 5 J 0 3 J 9 000V 3 000 V fencee miniDUOMD06 0 9 J 0 6 J 9 500V 3 500 V fencee miniDUOMD10 1 4...

Страница 2: ...563 01 Lan kroun I O 64793826 declares that the below listed products are in accordance with requirements of standards and regulations relevant for given type of devices Products are safe under condit...

Страница 3: ...ct with pulses conductors under normal operating conditions From the point of view of legislation especially the standard SN EN 60335 2 76 ed 2 Electric appliances for domestics and similar purposes S...

Страница 4: ...zer before carrying out any work on the electric fence system Read thoroughly the Safety Guidelines paragraph Strictly observe all safety guidelines during installation work Do not connect the device...

Страница 5: ...impulse lasts for a matter of milliseconds These fences serve not only to enclose an area but also act as a deterrent e g to protect against wild boars Benefits of electric fence systems Electric fenc...

Страница 6: ...ave energy during using a quality fence with a low load The LED indicator on the front side of the energizer shows the operation of the source and also signals a possible fault on the energizer The en...

Страница 7: ...nt water stream is avoided To mount energizer on wall use attached screws on which you can hang the energizer easily Assembly of energizer by using DIN rail Energizer can be easily and practically mou...

Страница 8: ...rew or DIN rail with mounting bracket in vertical position at least 20 cm above ground Never expose energizer to continuous water stream ON THE GROUND IN A PUDDLE ON THE GROUND UPSIDE DOWN NEGATIVE AN...

Страница 9: ...ded Distance of at least 10 meters must be between earthing rod of the fence system and another earthing system for example earthing of a house protective earthing of electric supply system or earthin...

Страница 10: ...y short press of button turning off the energizer 9 EXPLANATION OF THE LED INDICATOR SIGNALS LIGHT FLASHING FLASHING It signals the operation and flashes in interval of the individual pulses RAPID DOU...

Страница 11: ...ons of 100 200 mm It is either standard warning sign or contains the following Inscription on both sides WARNING ELECTRIC FENCE Letters must be at least 25 mm high and indelible One warning sign is in...

Страница 12: ...persons may gain ready access to the conductors Where an electric animal fence crosses a public pathway a non electrified gate shall be incorporated in the electric animal fence at that point or a cr...

Страница 13: ...rized service or another qualified person so that possibility of danger is excluded Service and repairs of these energizers must be performed by authorized persons only Each user of electric fence sys...

Страница 14: ...V and the fence system was automatically switched off This is to protect the battery from deep discharge destruction of the battery Replace the battery with a charged one or connect an adapter until t...

Страница 15: ...dress of guarantee provider can be found in attached instructions for use of given type of energizer Accumulators or batteries of any type damages due to overvoltage caused by lightning among others a...

Страница 16: ...ture of seller VNT electronics s r o Dvorsk 605 563 01 Lan kroun Czech Republic info fencee eu 420 730 893 828 24112022 PRINT fencee cz fenceeczech Electric fencing www fencee eu www fenceefarm com ww...

Отзывы: