background image

10

8. CONTROL

POWER SWITCHING – ON/OFF SWITCH BUTTON

The large switch button is used for basic control. This button turns the energizer on and off 

and it can be used to activate the Power save mode, i. e. to extend the interval between pulses. 

After switching off and then switching on, the energizer remembers the last set power.

IN SWITCHED-OFF CONDITION OF THE ENERGIZER

                  long press of button  (>2 s)  

  

switching energizer on.

                  short press of button   

  

no reaction.

IN SWITCHED-ON CONDITION OF THE ENERGIZER

 long press of button  (>2 s)   

   

manual switching between basic and Power  

 

save mode (approximately 2x longer delay) – 

selectable by the user, for 

 example if it is necessary to save the battery

short press of button   

  

turning off the energizer.

9. EXPLANATION OF THE LED INDICATOR SIGNALS

LIGHT/FLASHING

FLASHING

      

It signals the operation and flashes in interval of the individual pulses.

RAPID DOUBLE FLASHING 

(red)

The battery voltage has dropped below 12 V.

RAPID SHORT FLASHING 

(red) 

The energizer is switched off and the battery voltage is lower than 11,4 V.

COLOR

Blue

Operation in normal mode.

Purple

Power save mode, extended time between pulses.

Red

Indicates warning and error condition (for example battery voltage drop below 12 V) 

or a fence voltage drop below 2.5 kV.

When the battery voltage drops below 11,6 V, a warning siren (beeping) is switched on. If the 

voltage drops below 11,4 V, the fence system switched off.  The Energizer will only flash rapidly 

red and will not give an impulse. The reason is to protect the battery from deep discharge 

(battery destruction).

Содержание mini DUO MD03

Страница 1: ...30V 12V STORED ENERGY OUTPUT ENERGY OUTPUT VOLTAGE OUTPUT VOLTAGE500 SWITCHING ON OFF fencee miniDUOMD03 0 5 J 0 3 J 9 000V 3 000 V fencee miniDUOMD06 0 9 J 0 6 J 9 500V 3 500 V fencee miniDUOMD10 1 4...

Страница 2: ...563 01 Lan kroun I O 64793826 declares that the below listed products are in accordance with requirements of standards and regulations relevant for given type of devices Products are safe under condit...

Страница 3: ...ct with pulses conductors under normal operating conditions From the point of view of legislation especially the standard SN EN 60335 2 76 ed 2 Electric appliances for domestics and similar purposes S...

Страница 4: ...zer before carrying out any work on the electric fence system Read thoroughly the Safety Guidelines paragraph Strictly observe all safety guidelines during installation work Do not connect the device...

Страница 5: ...impulse lasts for a matter of milliseconds These fences serve not only to enclose an area but also act as a deterrent e g to protect against wild boars Benefits of electric fence systems Electric fenc...

Страница 6: ...ave energy during using a quality fence with a low load The LED indicator on the front side of the energizer shows the operation of the source and also signals a possible fault on the energizer The en...

Страница 7: ...nt water stream is avoided To mount energizer on wall use attached screws on which you can hang the energizer easily Assembly of energizer by using DIN rail Energizer can be easily and practically mou...

Страница 8: ...rew or DIN rail with mounting bracket in vertical position at least 20 cm above ground Never expose energizer to continuous water stream ON THE GROUND IN A PUDDLE ON THE GROUND UPSIDE DOWN NEGATIVE AN...

Страница 9: ...ded Distance of at least 10 meters must be between earthing rod of the fence system and another earthing system for example earthing of a house protective earthing of electric supply system or earthin...

Страница 10: ...y short press of button turning off the energizer 9 EXPLANATION OF THE LED INDICATOR SIGNALS LIGHT FLASHING FLASHING It signals the operation and flashes in interval of the individual pulses RAPID DOU...

Страница 11: ...ons of 100 200 mm It is either standard warning sign or contains the following Inscription on both sides WARNING ELECTRIC FENCE Letters must be at least 25 mm high and indelible One warning sign is in...

Страница 12: ...persons may gain ready access to the conductors Where an electric animal fence crosses a public pathway a non electrified gate shall be incorporated in the electric animal fence at that point or a cr...

Страница 13: ...rized service or another qualified person so that possibility of danger is excluded Service and repairs of these energizers must be performed by authorized persons only Each user of electric fence sys...

Страница 14: ...V and the fence system was automatically switched off This is to protect the battery from deep discharge destruction of the battery Replace the battery with a charged one or connect an adapter until t...

Страница 15: ...dress of guarantee provider can be found in attached instructions for use of given type of energizer Accumulators or batteries of any type damages due to overvoltage caused by lightning among others a...

Страница 16: ...ture of seller VNT electronics s r o Dvorsk 605 563 01 Lan kroun Czech Republic info fencee eu 420 730 893 828 24112022 PRINT fencee cz fenceeczech Electric fencing www fencee eu www fenceefarm com ww...

Отзывы: