Relay type 

3 contacts (Common, NC, NO)

Maximum current 

8A (resistive load)

Voltage 

250 Vac continuously

Instalable in 

Option1 and/or Option2 and/or Option3

Manufacturer  FEMA ELECTRÓNICA, S.A.

 

Altimira 14 - Pol. Ind. Santiga

 

E08210 - Barberà del Vallès

 

BARCELONA - SPAIN 

 

www.fema.es - [email protected]

Products -   M40-P

The manufacturer declares that the instruments indicated 

comply with the directives and rules indicated below.

Directive of electromagnetic compatibility 2004/108/CEE

Directive of low voltage 73/23/CEE

Security rules 61010-1

Equipment “Fixed” 

 

“Permanently connected”

Pollution degree 1 and 2 (without condensation) 

Isolation Double

Category CAT-II

Emission rules

61000-6-4   Generic rule of emission

Immunity rules

61000-6-2 

Generic rules of immunity

61000-4-2 

By contact ±4KV - Criteria B

 

On air ±8KV - Criteria B

61000-4-3  

Criteria A

61000-4-4   On AC power lines: ±2KV - Criteria B

 

On DC power lines: ±2KV - Criteria B

 

On signal lines : ±1KV - Criteria B

61000-4-5 

Between AC power lines ±1KV - Criteria B 

 

Between DC power lines ±0.5KV - Criteria B

61000-4-6 

Criteria A

61000-4-8 

30A/m at 50Hz - Criteria A

61000-4-11  0% 1 cycle Criteria A

 

40% 10 cycle Criteria A

 

70% 25 cycle Criteria B

 

0% 250 cycle Criteria B

Barberà del Vallès September 2011

Daniel Juncà - Quality Manager

All instruments are warranted against all manufacturing 

defects for a period of 24 MONTHS from the shipment date. 

This warranty does not apply in case of misuse, accident or 

manipulation by non-authorized personnel. In case of mal-

function get in contact with your local provider to arrange for 

repair. Within the warranty period and after examination by 

the manufacturer, the unit will be repaired or substituted when 

found to be defective. The scope of this warranty is limited to 

the repair cost of the instrument, not being the manufacturer 

eligible for responsibility on additional damages or costs. .

You may need to access the inside of the instrument to insert 

additional options. Use a flat screwdriver to unlock the upper 

clips marked with “A”. Then unlock the lower clips marked 

with “B” and move out the front filter. Let the inside of the 

instrument slide out of the housing.

To reinsert the instrument make sure that all modules are 

correctly connected to the pins on the display module. Place 

all the set into the housing, assuring that the modules cor-

rectly fit into the internal guiding slides of the housing. Once 

introduced,  place  again  the  front  filter  by  clipping  first  the 

upper clips “A” and then the lower clips “B”.

Important - If your instrument was delivered with the IP65 

front seal option, accessing the inside of the instrument will 

permanently break the IP65 seal on the areas of  clips “A” 

and “B”.

Option R1 - 1 relay

Warranty

CE Declaration of Conformity

Accessing the instrument

Connections for Option3*

(*Option3 available soon)

Connections for Option1 and 2

B C D

Com.

NO

NC

L M

 N

Com.

NO

NC

G H I

A

B

Datasheet

Sales:

 

+44 (0) 1273 570 220   

Website:

 www.amplicon.com   

Email:

 [email protected]

       IT and Instrumentation for industry

 Amplicon.com

Содержание M40 Series

Страница 1: ...ers Segment linearization maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Univers...

Страница 2: ...n ways not specified by the manufacturer may lead to a reduction on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action Risk...

Страница 3: ...e power line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag Signal Cu...

Страница 4: ...ns and rear jumper for signal selec tion in Vdc or mA Functions available Segment linearization 10 segments Fixed digits yes configurable Filter on display yes recursive configurable Steps yes configu...

Страница 5: ...llows to select each digit for modification with the UP button Reset Leaving the Configuration Menu forces a restart of the instrument even in case of no changes in configuration Configuration See men...

Страница 6: ...rm as maximum Alarm as minimum Counts Seconds Second setpoint Auto correction Auto High Auto Low Alarms Signal Low Display Low Signal High Display High Steps Counts for step Average Display Fixed Digi...

Страница 7: ...ault brightness Range and scaling 4 20mA 0 1000 Decimal point without decimal point Alarms 1 2 3 and 4 Active Off not managed Type maximum Setpoint 1000 Hysteresis 0 counts Delay 0 0 seconds Setpoint2...

Страница 8: ...Left Zero LZEr Value On Off Select On to visualize zeros to the left Add Right Zero rZEr Add a zero to the right Value On Off Select On to light a fifth digit on the display placed to the right LSD p...

Страница 9: ...alues are activated The slope defined by the two points is almost vertical higher than 5000 Err 1 Password incorrect Err 2 The instrument has detected an installed option but was unable to communicate...

Страница 10: ...f misuse accident or manipulation by non authorized personnel In case of mal function get in contact with your local provider to arrange for repair Within the warranty period and after examination by...

Отзывы: