manualshive.com logo in svg
background image

Model M40-P 

for process signals

( ±20mA and ±10Vdc)

Series M40

Panel meter for process signals in mA and Vdc. Accepts both active and passive 

signals, monopolar and bipolar, from 2 and 3 wire transducers. 

Housing 96x48mm DIN 

standard. Display in 4 or 5 digits.

 Provides excitation voltage for transducers. Segment 

linearization, 

maximum and minimum display memory, scalable reading, filters, steps, 

signal autocorrection, “measure” function, peak&hold, alarms with double setpoints, 5 

levels of brightness, ... Universal AC and DC power modules and up to 3 modules for 

signal retransmission and control.

Panel Meters

FEMA ELECTRÓNICA

USER’S MANUAL

(2145R00)

Panel meter 96x48mm

Datasheet

Sales:

 

+44 (0) 1273 570 220   

Website:

 www.amplicon.com   

Email:

 [email protected]

       IT and Instrumentation for industry

 Amplicon.com

Содержание M40 Series

Страница 1: ...ers Segment linearization maximum and minimum display memory scalable reading filters steps signal autocorrection measure function peak hold alarms with double setpoints 5 levels of brightness Univers...

Страница 2: ...n ways not specified by the manufacturer may lead to a reduction on the specified protection level Disconnect the instrument from power before starting any maintenance and or installation action Risk...

Страница 3: ...e power line a protection fuse acting as disconnection element easily accessible to the operator and identified as a protection device Power H fuse 250mA time lag Power L fuse 400mA time lag Signal Cu...

Страница 4: ...ns and rear jumper for signal selec tion in Vdc or mA Functions available Segment linearization 10 segments Fixed digits yes configurable Filter on display yes recursive configurable Steps yes configu...

Страница 5: ...llows to select each digit for modification with the UP button Reset Leaving the Configuration Menu forces a restart of the instrument even in case of no changes in configuration Configuration See men...

Страница 6: ...rm as maximum Alarm as minimum Counts Seconds Second setpoint Auto correction Auto High Auto Low Alarms Signal Low Display Low Signal High Display High Steps Counts for step Average Display Fixed Digi...

Страница 7: ...ault brightness Range and scaling 4 20mA 0 1000 Decimal point without decimal point Alarms 1 2 3 and 4 Active Off not managed Type maximum Setpoint 1000 Hysteresis 0 counts Delay 0 0 seconds Setpoint2...

Страница 8: ...Left Zero LZEr Value On Off Select On to visualize zeros to the left Add Right Zero rZEr Add a zero to the right Value On Off Select On to light a fifth digit on the display placed to the right LSD p...

Страница 9: ...alues are activated The slope defined by the two points is almost vertical higher than 5000 Err 1 Password incorrect Err 2 The instrument has detected an installed option but was unable to communicate...

Страница 10: ...f misuse accident or manipulation by non authorized personnel In case of mal function get in contact with your local provider to arrange for repair Within the warranty period and after examination by...

Отзывы: