IMPORTANT SAFETY INFORMATION
36
MU2B-0375GE51 R0616C
IMPORTANT SAFETY INFORMATION
Please read this before installation and commissioning!
Installation and Commissioning
Thermostats may be installed only by
personnel trained in this application
area in accordance with the
installation instructions and local legal
requirements.
Thermostats should always be
installed using suitable thermo-wells.
Never dip sensors of the series TAM
and TX directly into the medium.
Before selecting a thermowell, always
check for material compatibility with
measured medium.
Caution when touching the device –
risk of burns. Thermostats can reach
a medium temperature of up to 130
°C. Risk of freezing at temperatures
below the freezing point.
ATTENTION: In no case is the wiring
box or plug to be opened or the
terminals to be wired before the
device is de-energized.
The device must be used only within
the electrical and thermal limits
specified in the data sheet.
Inductive loads can cause contact
burns or fuse the contacts. Pre-
ventative measures must be
implemented by the customer, e.g.,
by using suitable RC elements.
Devices must be protected from solar
radiation and rain.