FEMA ELECTRÓNICA . Series C . C40-D
25
1.31 Precautions on installation
1.32 Factory configuration
This instrument is warranted against all manufacturing defects for a period
of 24 months, as requested by the European legislation. This warranty does
not apply in case of misuse or accident, and the scope of the warranty is lim
-
ited to repair of the instrument, not being the manufacturer responsible for
additional damages or additional costs. Within the warranty period and after
examination by the manufacturer, the unit will be repaired or substituted
when found to be defective.
Extended warranty available at www.fema.es / docs / 4153_Warranty1_
1.33 Warranty
Range
600 Vac
Scaling and decimal point
0/600 Vac = 0/600
Alarms 1
Type
alarm as maximum
Setpoint
1000
Hysteresis
0 counts
Alarm 2
Type
alarm as maximum
Setpoint
1000
Hysteresis
0 counts
External control
off
Fast access
all off
Tools
Option.1
off
(retains last configuration value)
Step
1
Average
0
Offset reading
0
Second scaling
0/600
‘Eco’ mode
off
Temperature resolution
1º
Degrees
ºC
Alpha
385
cJc
on
AC deadband
20
Brightness
3
Password
off
Option 1 configuration
Option analog output
0/100.0=4/20 mA
Option serial Modbus RTU 9600 bps, address 1, format 8n1
Jumpers ‘S’
selected for 600 Vac
Jumper ‘T’
selected for ‘EK’ external control function
1.34 CE declaration of conformity
Manufacturer FEMA ELECTRÓNICA, S.A.
Altimira 14 - Pol. Ind. Santiga
E08210 - Barberà del Vallès
BARCELONA - SPAIN
www.fema.es - [email protected]
Products
C40-D
The manufacturer declares that the instruments indicated comply with the
directives and rules indicated below.
Electromagnetic compatibility directive 2014/30/EU
Low voltage directive 2014/35/EU
ROHS directive 2011/65/EU
WEEE directive 2012/19/EU
Security rules EN-61010-1
Instrument
Fixed, Permanently connected
Pollution degree 1 and 2 (without condensation)
Isolation
Double
Category
CAT-III up to 300V
CAT-II up to 600V (only with ‘Pollution degree 1’)
Electromagnetic compatibility rules EN-61326-1
EM environment Industrial
CISPR 11
Instrument Class A & Class B Group 1
For a detailed declaration see document www.fema.es / docs / 4152_CE-
Barberà del Vallès, January 2017
Xavier Juncà - Product Manager
According to directive 2012/19/EU, electronic equip-
ment must be recycled in a selective and controlled
way at the end of its useful life.
This instrument has been designed and verified conforming to the 61010-1 CE Security
Regulation, for industrial applications. Installation of this instrument must be performed
by qualified personnel only. This manual contains the appropriate information for the in
-
stallation. Using the instrument in ways not specified by the manufacturer may lead to a
reduction of the specified protection level. Disconnect the instrument from power before
starting any maintenance and / or installation action.
The instrument does not have a general switch and will start operation as soon as power is
connected. The instrument does not have protection fuse, the fuse must be added during
installation.
The instrument is designed to be panel mounted. An appropriate ventilation of the in
-
strument must be assured. Do not expose the instrument to excess of humidity. Maintain
clean by using a humid rag and do NOT use abrasive products such as alcohols, solvents,
etc. General recommendations for electrical installations apply, and for proper functional
-
ity we recommend : if possible, install the instrument far from electrical noise or magnetic
field generators such as power relays, electrical motors, speed variators, ... If possible, do
not install along the same conduits power cables (power, motor controllers, electrovalves,
...) together with signal and/or control cables. Before proceeding to the power connection,
verify that the voltage level available matches the power levels indicated in the label on
the instrument. In case of fire, disconnect the instrument from the power line, fire alarm
according to local rules, disconnect the air conditioning, attack fire with carbonic snow,
never with water.
Risk of electrical shock. Instrument terminals can be connected
to dangerous voltage.
Instrument protected with double isolation. No earth connection
required.
Instrument conforms to CE rules and regulations.