Fema Electronica K40-CR Скачать руководство пользователя страница 2

FEMA ELECTRÓNICA . Series K . K40-CR

2

1. Panel meter K40-CR

Chronometer and time counter, size 96

x

48

mm (1/8 DIN), with 20 mm digit height

Panel  meter  96 x 48 mm  (1/8  DIN)  and  4  digits  with  20 mm  digit 

height, and function chronometer and time counter. Time displayed 

in  different  formats  covering  hours,  minutes,  seconds  and  days. 

Reading configurable in decimal and sexagesimal (clock) formats. Up 

and down counting functions, with configurable preset value.

Controls

Independent controls for ‘start’, ‘stop’ and ‘reset’ 

(see section 1.6)

Controls activated by default through free potential contacts. Con

-

figurable for activation with other control signals (NPN, PNP, induc

-

tive, ...).

Reset

Reset control is provided by connection at the rear of the instrument, 

configurable to activate by edge or by level. Front reset configurable 

at  the  ‘LE’  keypad 

(see  section  1.7). 

Automatic  reset  configurable 

when reaching an alarm setpoin

(see section 1.7).

Special functions

Special functions with activation by connection at the rear of the in

-

strument. Includes control for counting direction, total accumulated 

times, total exceeded time, hold of display reading and memory of 

cicles 

(see section 1.12.2).

Alarms

Independent  alarms  configurable  as  maximum  or  minimum,  with 

configurable activation and deactivation delays and optional invert

-

ed activation of the relay. Alarms configurable in ‘normal’ mode or 

‘repeat’ mode. In ‘repeat’ mode the alarm activates every time the 

configured setpoint time has passed 

(see section 1.12.4)

.

The ‘on_alarm’ parameter allows to associated a predefined function 

to the activation of the alarm. Available functions are : stop counting, 

activate the reset, set reading to ‘0’ or continue. Use ‘on_alarm’ con

-

figured to ‘reset’ to implement repetitive cycles of time which can be 

counted by special function ‘B.2’ 

(see section 1.12.2).

Flash

Several options allow to configure the display flash in case of ‘stop’ 

or ‘start’ counting, or in case of alarm activation 

(see section 1.12.4).

Security on start-up

The ‘On power-up’ function defines a time of inactivity of the instru

-

ment after power-up, the status of the instrument (‘start’ or ‘stop’) 

after power-up, and the option to apply a reset after power-up 

(see 

section 1.12.2).

Memory

The instrument saves and recovers the last reading value in case of 

power-loss.

Configurable ‘

fast-acess’

 menu

The front key ‘UP’ () gives access to a user configurable menu with 

direct access to several useful functions such as alarm setpoints and/

or preset value 

(see section 1.12.5).

Control and retransmission options

Options for output and control with 1, 2 and 3 relays, transistor out

-

puts, controls for SSR relays, isolated analog outputs, communica

-

tions in Modbus RTU, RS-485 ASCII and RS-232. Special options with 

4 and 6 relay outputs.

Mechanical

Front protection IP65. Connections by plug-in screw terminals. For 

industrial applications.

1.1 

How to order

K40

CR

Model

Power

-

Option 1

Others

H

-

-

-

Option 2

-

Option 3

-

-R1

 

(1 relay)

-AO

 

(analog output)

-RTU

 

(Modbus RTU)

-S4

 

(RS-485)

-S2

 

(RS-232)

-T1

 

(1 transistor)

-SSR

 

(1 control SSR)

(empty)

-H 

(85-265

Vac/dc)

-L 

(11/60

Vdc, 

 

 

24

Vac, 48

Vac)

-NBT 

(no buttons)

-65 

(front IP65)

-G 

(green led)

Содержание K40-CR

Страница 1: ...4 digit display Fast access to alarm setpoints special modes for counting exceeded time and totalized counting times on power up function configurable led brightness Universal AC and DC power Up to 3...

Страница 2: ...nt time has passed see section 1 12 4 The on_alarm parameter allows to associated a predefined function to the activation of the alarm Available functions are stop counting activate the reset set read...

Страница 3: ...1 12 9 Function Password 13 1 12 10 Factory reset 13 1 12 11 Firmware version 13 1 12 12 Brightness 13 1 12 13 Access to optional modules 13 1 13 Full configuration menu 14 1 14 Factory configuration...

Страница 4: ...nnection for correct operation nor for com pliance with the security regu lations 8 9 0 Fuse To comply with security regulation 61010 1 add to the power line a protection fuse acting as disconnection...

Страница 5: ...ation menu a B function automatically activates the alternative connections mode The reset function can be activated from three independent and con figurable sources Front reset associated to the fron...

Страница 6: ...e 18Vdc 15Vdc 9 Vdc 5Vdc maximum current 70 mA protection yes current limited to 70 mA Display refresj 12 refresh second retention memory yes recovers counting value in case of power loss Power power...

Страница 7: ...a ENTER key It selects and accesses the menu option currently dis played At menus with numerical value entries it validates the num ber displayed Key UP 5 the UP 5 key gives access to the fast access...

Страница 8: ...nstrument The On Power Up on Pu menu configures functions to apply at start up It applies only to instrument restart after power loss It does not apply to instrument restart due to change in configura...

Страница 9: ...n to add 1 each time alarm 1 activates on alarm 2 o AL2 select on to add 1 each time alarm 2 activates on alarm 3 o AL3 select on to add 1 each time alarm 3 activates on reset o rSt select on to add 1...

Страница 10: ...inimum value if the actual value is smaller It replaces the maximum value if the actu al value is larger Minimum and maximum values are visible through front key UP 5 see section 1 12 5 Application a...

Страница 11: ...e independent activation of up to 3 relay outputs or transistor or SSR control installed with the R1 or T1 or SSr optional modules see section 2 1 For outputs up to 4 and 6 relays see special modules...

Страница 12: ...top to stop the counting set the Alarm flash AL FL parameter to on to activate the flash of the display when alarm is active To manually deactivate the flash mode press any of the front keys or change...

Страница 13: ...Password PASS menu select a 4 digit code to block access to the configuration menu Instrument configuration will not be ac cessible to non authorized personnel To activate the Password se lect on and...

Страница 14: ...s access to the configuration parameters of the channel B function Fn b previously selected If no function has been selected menu entry indicates Fn b n Following is an explanation for menus Fn b 1 to...

Страница 15: ...delay Inverted relay Locked alarm Disabled Normal Repeat Stop Alarm flash Controls Activation for Start and Stop Pulls for reset Pulls for Start and Stop Activation for reset Pull down No pull Pull u...

Страница 16: ...et activates by edges EdGE Function on channel B no Controls Pulls for start and stop pull up P uP Activation for start and stop by falling edge on_0 Pulls for reset pull up P uP Activation for reset...

Страница 17: ...ment is variable and the operator requires that the setting of each drying time to be easily accessible and modifiable The modification of other configuration parameters must be locked During the proc...

Страница 18: ...ualified personnel only To open the housing use a flat screwdriver to free the fixation clips if possible in the following order D C B and A Remove the front cover Let the inside of the instrument sli...

Страница 19: ...nd regulations 1 20 Warranty This instrument is warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident or...

Страница 20: ...ntinuous Isolation 3500 Veff Type of terminal plug in screw terminal pitch 5 08 mm Slots allowed Opt 1 Opt 2 Opt 3 Terminal A Common Terminal B NO Normally open Terminal C NC Normally closed Power Opt...

Страница 21: ...special configuration Terminal A Vexc Terminal B Signal in mA or Vdc Terminal C GND Jumper M closed for mA Jumper V closed for Vdc For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_man...

Страница 22: ...Opt 2 Opt 1 Opt 3 B A G B A G Signal B A G Terminal B B signal from RS 485 bus Terminal A A signal from RS 485 bus Terminal G GND For more information http fema es docs 4254_SERIES_M K S_ OPTIONS_manu...

Страница 23: ...programs Access to display values alarm status memory of maximum and minimum alarm setpoints Configuration from instrument front keypad through menu entries Opt 1 Opt 2 or Opt 3 depending on the posit...

Страница 24: ...without front key pad To configure the instrument remove the meter from the panel and remove the front filter Inter nal press buttons for configuration are accessible Optionally request the instrument...

Страница 25: ...lder 4 1 THM benchtop housing Adapter96 x 96 mmfor96 x 48 mm instruments Adapter for DIN rail mount for Series M and Series K of panel meters Front IP65 protector for Series M and Series K of panel me...

Страница 26: ...FEMA ELECTR NICA Series K K40 CR 26 Notes...

Страница 27: ...FEMA ELECTR NICA Series K K40 CR 27 Notes...

Страница 28: ......

Отзывы: