Page : 9
9.5.- SENSOR CONNECTIONS FOR MODELS BDF-XX-T1, BDF-XX-T2 and BDF-XX-TF
PNP or NPN Sensor .
PICK-UP Sensor .
NAMUR Sensor .
Channel 1
Pulses by Channel 1 (terminal C).
INHIBIT or UP/DOWN controls by Channel 2 (terminal D, see paragraph 9.3.- RESET AND
CONTROL CONNECTIONS).
V
EXC.
= +15 Vdc.
0 Vdc.
E
D
C
A
B
PNP or NPN
Sensor.
V
EXC.
= +15 Vdc.
0 Vdc.
E
D
C
A
B
9.6.- SENSOR CONNECTIONS FOR MODEL BDF-XX-T3
The display will add all the pulses arrived by Channel 1 (terminal C) and will subtract all the pulses
arrived by Channel 2 (terminal D).
9.7.- SENSOR CONNECTIONS FOR MODEL BDF-XX-T5 and BDF-XX-T6
V
EXC.
= +15 Vdc.
0 Vdc.
E
D
C
A
B
ENCODER
Channel 1
Channel 2
Channel 2
Channel 1
Channel 2
Channel 1
90º
PNP or NPN Sensor.
PNP or NPN Sensor.
For mechanical closure, se-
lect the jumpers on the S1
selector using the PNP
configuration. See page 7.
For mechanical closure, se-
lect the jumpers on the S1
selector using the NPN
configuration. See page 7.
For mechanical closure,
select the jumpers on the
S1 selector using the NPN
configuration. See page 7.
For mechanical closure,
select the jumpers on the
S1 elector using the PNP
configuration. See page 7.
The signal on Channel 2 is a
pulse train signal shifted 90º
a w a y f r o m t h e s i g n a l o n
Channel 1.