AXISS DIGITAL SMARTVIEW INSTALLATION GUIDE

15V    ACCU      

            EXT           R

S-232      M

OTOR          

    TLI                      A

UX

    

4

 

Remove the cover

Wire (not supplied)

Conduit (not supplied)

The draw wire should be fitted before the wall is lined.

NOTE:

 Feeding a string or wire through the Control Housing and conduit will make it easier to pull the 

cables through to the TLC 30 FTD. 

3

 

Draw wire through the Control Housing

DIGITAL MIXER INSTALLATION

Содержание Axiss Smartview FD-SVCSMC

Страница 1: ...1 AXISS DIGITAL SMARTVIEW INSTALLATION GUIDE INSTALLATION GUIDE AXISS Smartview Digital Thermostatic Shower Mixer FD SVCSMC...

Страница 2: ...2 FELTON...

Страница 3: ...Interface Pre Line Installation 8 Operational Test 19 Notice 5 Measurements 6 Tools Required 5 Scope of Application 7 Digital Mixer Installation 9 Vision Wheel Interface Final Fit Installation 14 Tro...

Страница 4: ...4 FELTON...

Страница 5: ...LECTRIC SHOCK ELECTRICAL INSTALLATION Before opening the housing the mains connection must be switched off Work on electrical parts and connections must be carried out by qualified electrician Country...

Страница 6: ...mm 6 Control Wheel 1 Temperature Flow Control Unit 3 Set of Screws 2x 5x50mm 2 Back Up Battery 4 Connecting Adapters 2 Display Unit black or white 4 Fastening Seal Kit silicone seal black foam seal wa...

Страница 7: ...st be within 1m from the digital mixer Cable length 6m max Hot in Cold in Digital Mixer Handset xed head outlets CONTROL UNIT Pipework in Control cable Pipework out Power supply Note The wheel can be...

Страница 8: ...ter hole is required in a fixing nog flush with face of the timber framing Conduits should be used in the walls where necessary to protect the cables and allow maintenance Attach the Control Housing u...

Страница 9: ...the cover Wire not supplied Conduit not supplied The draw wire should be fitted before the wall is lined NOTE Feeding a string or wire through the Control Housing and conduit will make it easier to pu...

Страница 10: ...S 232 MOTOR TLI AUX Outlet HOT COLD Inlets Fixing holes Cover retaining holes Connector block Power supply Battery compartment 1 2 Connects to hand shower 1 Connects to fixed head 2 5 Inside the Tempe...

Страница 11: ...Flow Control Unit must be acessible and dry Use the processor template on the last page to mark the position of the fixing holes in the selected location ORIENTATION FOR WALL SITUATION MOUNTING OPTIO...

Страница 12: ...X Fully insert the inlet adapters into the inlet valves one long and one short adapter 8 Connect hot and cold water supply IMPORTANT Flush the pipework before connection A B Connect hot and cold water...

Страница 13: ...RT Insert outlet adapters and connect outlet pipeworks Primary outlet Hand Shower Secondary outlet Fixed Head 1 2 If using two outlets Connect outlet and outlet 1 2 If only using single outlet Outlet...

Страница 14: ...les should be drilled in the tile etc to finish Draw a line around the collar flush with the wall Cut down the collar as marked Final wall lining Final wall lining 12 Tighten adapter retaining bolt 1...

Страница 15: ...trol Housing Feed data cable through silicone seal and black foam seal Secure both cables to the previously installed draw wire and pull the cables to the Temperature Flow Control Unit 60mm 5mm 40mm 5...

Страница 16: ...Control Housing into the Display Unit and lock by turning clockwise 2 Fit Control Wheel 3 16 Position Display Unit and attach with screws 1 Push and twist to lock ADVICE Push in firmly Fit silicone se...

Страница 17: ...Place back up battery in shown location within the Temperature Flow Control Unit and connect cable to ACCU port Note After installation battery may require 24 hours of charging on mains power before b...

Страница 18: ...o the RS 232 port as shown 1 DISPLAY UNIT BLACK CABLE IMPORTANT Electrical supply must be installed by a qualified electrician if required Fit the cover back on to the base using a Phillips screwdrive...

Страница 19: ...Push the Smartview Interface again The Digital Mixer closes and the LED goes off 1 Ensure that the Digital Mixer is installed correctly installed according to the instructions above Turn on the water...

Страница 20: ...Difference in supply pressure between hot and cold water greater than 100kPa Balance pressure to eliminate difference Constant flow of water Unit will not turn off Carry out function Self Check Diagno...

Страница 21: ...not cover any damage to product due to abuse negligence or improper installation This warranty is given on the understanding that the product is installed by a registered plumber and operated accordin...

Страница 22: ...22 FELTON...

Страница 23: ...23 AXISS DIGITAL SMARTVIEW INSTALLATION GUIDE 8 x 55 8 x 55 this side up this side up 235mm SMARTVIEW PROCESSOR TEMPLATE...

Страница 24: ...ELTON felton industries limited FeltonIndustriesLimited feltonltd feltonltd feltontapware FELTON INDUSTRIES LTD 8 Farmhouse Lane St Johns Auckland 1072 sales felton co nz Find us on Social Media 15032...

Отзывы: