background image

5

4

AM-PRO UI & INDICATOR LAYOUT

PROJECT:

DATE:

REV:

AUTHOR:

COPERFIELD

03-AUG-16

X4

M. GARTZ

OPERATION

The air purifier continuously works in automatic mode; the user can select which preference they would like the purifier to use based on the location or desired 

operation of the air purifier. The purifier will operate through a minimized range of speeds, not exceeding the maximum level selected, in order to run quietly while 

cleaning the room of contaminants. Once air is cleaned, and no sensors are activated, the unit lowers to energy saving mode to reduce energy consumption and 

extend the life of the filters. 
When Auto Mode is selected, the Auto mode indicator will be blue. This mode uses the EnviroSmart™ technology to monitor the air quality, motion and noise level 

to adjust the fan speed in order purify your air as quickly as possible. Once air is cleaned, and no sensors are activated, the unit lowers to energy saving mode to 

reduce energy consumption and extend the life of the filters.
When Quiet Mode is selected, the Auto Mode indicator will be purple. The machine will continue to use EnviroSmart™ but only utilizes the 3 lowest, most quiet of 

the 5 fan speeds. 
When Manual Mode is selected, the Manual mode indicator will be blue. This mode allows you to choose one of the 5 fan speeds and keep unit at this speed until 

Auto Mode is chosen/selected. EnviroSmart™ sensors will NOT adjust the fan speed in this mode.

DISPLAY PANEL

HEPA FILTER REPLACEMENT INDICATOR

 – 

This indicator will show 

its status when the access panel is open or closed. If the light is red this indicates 

the filter needs replacing. The replacement period will vary depending on the 

filters used, hours of use, air quality, and rate of air flow. For filter replacement 

indicator descriptions see 

FILTER REPLACEMENT INDICATORS

 section. 

CARBON FILTER REPLACEMENT INDICATOR

 – 

This indicator will 

show its status when the access panel is open or closed. If the light is red this 

indicates the filter needs replacing. The replacement period will vary depending 

on the filters used, hours of use, air quality, and rate of air flow. For filter 
replacement indicator descriptions see 

FILTER REPLACEMENT INDICATORS

 section.

ACCESSORY INDICATOR

 –

 

This indicator will show its status when the 

access panel is open or closed. This indicator will only be used if an accessory filter 

is installed in the unit. If the light is red this indicates the filter needs replacing. 

The replacement period will vary depending on the filters used, hours of use, air 

quality, and rate of air flow. For filter replacement indicator descriptions see 

FILTER 

REPLACEMENT INDICATORS

 section.

AIR QUALITY SENSOR

 – 

This indicator will show its status when the 

access panel is open or closed. This indicator monitors the air quality and adjusts 

the fan speed to keep your air purified. Blue, amber, and red lights indicate the 

purity of your air. 

PlasmaTRUE™ TECHNOLOGY

 –

 This indicator will show its status when 

the access panel is open or closed. Creates an ionized field to help safely remove 

airborne pollutants. To turn on and off the PlasmaTRUE™ TECHNOLOGY, touch 

and hold the PLASMA indicator. A blue light illuminates when the PlasmaTRUE™ 

TECHNOLOGY is enabled. To disable the PlasmaTRUE™ TECHNOLOGY, press and hold 

“Plasma” indicator until light is off.

AUTO MODE

 – 

To select, press and hold the button until the icon illuminates. 

This mode uses the EnviroSmart™ technology to monitor the air quality, motion and 

noise level to adjust the fan speed in order to purify your air as quickly as possible. 

This button also includes QUIET MODE. To select, press and hold until the button turns 

purple. The machine will continue to use EnviroSmart™ but only utilizes the 3 lowest, 

most quiet of the 5 fan speeds.

MANUAL MODE

 – 

To select, press the button until the icon illuminates. This 

mode allows you to choose one of the 5 fan speeds and keep the unit at this speed 

until AUTO MODE is chosen again. The internal sensors will not adjust the fan speed 

in this mode. 

FAN SPEED INDICATORS

 – 

The fan has 5 speeds and can reach turbo 

speed to clean the room in case of high levels of contaminants. The number of bars 

illuminated indicates fan speed. 

1

5

2

6

3

7

8

4

1

2

3

4

5

6

7

8

NOTE: after the unit is turned on the “AQ” light will flash for a few minutes while the system self-calibrates.

1 – whisper
2 – low
3 – medium

4 – high
5 – turbo

CARE AND MAINTENANCE

CLEANING:

 

•  Clean external housing as necessary by wiping with a dry, soft cloth; for stains, use a warm, damp cloth.

 

•  Do not use volatile fluids such as benzene, paint thinner, scouring powder or other cleaners that may damage the unit surface.

 

•  Clean intake and exhaust vents by wiping with a dry, soft cloth.

Unlock access panel: to unlock, insert 

the key provided and rotate counter-

clockwise ¼ turn.

Touch and hold the illuminated 

indicator for three seconds 

until a beep is heard and the 

indicator is flashing green.

Open front access panel by pressing 

latches on both sides of unit. Allow 

panel to open fully. Remove filter(s) 

to be replaced. 

Release finger from indicator.

Remove any packaging wrap from the 

new filters(s) and re-install the filters.

Touch and hold the indicator for 

three seconds until a beep is heard 

and the indicator light turns off.

1

FILTER REPLACEMENT INDICATORS:

The replacement filter indicators will signal when to replace the HEPA Filter and/or Carbon with Pre-Filter. The replacement period will vary depending on the hours of use, air 

quality, and rate of air flow. However, under normal usage, most HEPA Filters need to be replaced every 2 years, and Carbon with Pre-Filter every 6 months. When a filter needs to 

be replaced the following color will be shown on any one of the HEPA, CARBON, or ACCESSORY filter replacement indicators:
 

Red Flashing = RIGHT filter 90% full

 

Amber Flashing = LEFT filter 90% full

 

Red Flash, Pause, Amber Flash, Pause = Right & LEFT filters 90% full

 

Red = Replace RIGHT filter

 

Amber = Replace LEFT filter

 

Red & Amber Alternating = Replace Right & Left filters

Do not wash and reuse any of the filters – they will not work effectively. Only use AeraMax® PRO brand replacement filters as units will not function using any other 

replacements.

FILTER REPLACEMENT PROCEDURE:

FILTER REPLACEMENT:

When installing a new filter the unit will automatically detect the filter type but the user will have to manually reset the filter replacement indicators. To reset the flashing filter 
replacement indicator use the following procedure:

TROUBLESHOOTING

PROBLEM:

POSSIBLE SOLUTION:

The air quality control system fails to start.

•  Check to assure unit is connected to power supply.
•  Make sure filters are genuine AeraMax

® 

PRO filters, as unit will not function with other  

  brands. IMPORTANT: Make sure filter detection area on genuine AeraMax

® 

PRO  

  replacement filter aligns with window in filter frame.
•  Review “Re-Installing Filters” section for further detail.
•  Make sure front access panel is closed completely.
•  Make sure power switch is on.

The unit makes a faint ticking sound.

• 

This indicates that the “PlasmaTRUE™” bipolar ionizer is working.

The HEPA and/or Carbon Filter replacement indicator light 

remain lit after replacing the filter(s).

•  Repeat filter light reset instruction.

Note: If you do not complete step three within 10 seconds of completing step 1 then the indicator light will not be reset.

2

3

1

2

3

Содержание AERAMAX PRO AM4S PC

Страница 1: ...9057 CUSTOMER SERVICE SUPPORT www fellowes com PLEASE READ THESE INSTRUCTIONS BEFORE USE DO NOT DISCARD KEEP FOR FUTURE REFERENCE VEUILLEZ LIRE CES INSTRUCTIONS AVANT D UTILISER L APPAREIL NE PAS JET...

Страница 2: ...If the power plug is damaged it must be replaced by the manufacturer or a qualified technician Remove the power plug from the outlet before cleaning the unit When removing the power plug grasp by hol...

Страница 3: ...press and hold until the button turns purple The machine will continue to use EnviroSmart but only utilizes the 3 lowest most quiet of the 5 fan speeds MANUAL MODE To select press the button until th...

Страница 4: ...HEPA authentique avec traitement antimicrobien AeraSafe dont la dur e de vie estim e est de 1 an 2 filtres charbon actif avec pr filtre dont la dur e de vie moyenne est de 6 mois Syst me de nettoyage...

Страница 5: ...lateur les plus basses et les plus silencieuses sur les 5 existantes MODE AUTO pour effectuer une s lection appuyer sur le bouton puis le maintenir enfonc jusqu ce que l ic ne s allume Ce mode permet...

Страница 6: ...reemplazado por el fabricante o un t cnico calificado Quite el enchufe del tomacorriente antes de limpiar la unidad H galo sujetando el enchufe nunca tirando del cable Quite el enchufe del tomacorrien...

Страница 7: ...3 velocidades m s bajas y m s silenciosas de las 5 velocidades del ventilador MODO MANUAL para seleccionar este modo presione el bot n hasta que se ilumine el icono Este modo le permite elegir una de...

Страница 8: ...15 14...