Technical
Data
16
17
Dimensions
Opera�on and display
7” touchscreen, resis�ve
Housing
Housing material
Galvanised steel
Protec�on type
IP 20
Environmental condi�ons
Opera�on temperature
0…50°C
Humidity
0…90% rel. humidity, no condensa�on
Storage temperature
-25…+75 °C
Mains supply
Supply voltage
3x 400 V AC, N, PE
Switchable to
3x 230 V AC, PE
Tolerance
+ 10% / -15%
Power consump�on
when idle
7 W + 5 W per power board
Control voltage
Internal control voltage
+24VDC
Protec�on
1 x 2A medium delay (5 x 20mm)
Thermocouple inputs
Thermocouple
FeCuNi (TYPE J) 0..830° switchable to: NiCr-Ni (TYPE K) 0..830°
Cold junc�on compensa�on
Integrated
Resolu�on
0.1 K
Accuracy
+/- 0,25K
Load outputs
Bistable, electrically insulated
per zone
1x hea�ng, 230V AC switching
Control �me (phase angle /pulse package
10 ms at 50 Hz – 8.3 ms at 60 Hz
Current per zone
max. 16 A with 80% switch-on dura�on per zone
Minimum load
100W
Cau�on: observe the total load capacity of the electrical connec�on cable
Signal shape
Pulse opera�on/phase control (automa�c or manual selec�on)
Protec�on
2-pole; 6.3 x 32 mm
Internal: SIBA TYPE 16A T
External SIBA TYPE 16A GRL
Only use these fuse types!
2-polig; 6,3 x 32 mm
Intern: SIBA TYPE 16A T
Extern: SIBA TYPE 16A GRL
Nur diese Sicherungstypen verwenden!
Alarm no�fica�on outputs
3x relay contact
Poten�al-free for max. 250 VAC
Maximum current
4 A for cos
�
= 1; 2A for cos
�
= 0.5
Digital inputs
Insulated, poten�al-free
16 – 30 V DC
Data interfaces
Ethernet
CAT 5
RS485
D-SUB 9-pole
USB
USB 3.0 Standard
Tabletop devices 6/12 Zones
Tabletop devices 18/24 Zones
Содержание MCS
Страница 5: ......
Страница 10: ...Dimensions 18 19 Tabletop devices 30 36 Zones Large units on rollers 42 to 120 zones...